1
traceroute from pinger.seecs.edu.pk (Islamabad) to www.upesh.edu.pk (Peshawar)
1 115-186-131-65.nayatel.pk (115.186.131.65) 0.611 ms 0.752 ms 0.826 ms *[Islamabad]* 2 115-186-128-177.nayatel.pk (115.186.128.177) 0.814 ms 0.649 ms 0.678 ms *[Islamabad]* 3 58-65-175-2.nayatel.pk (58.65.175.2) 2.988 ms 2.302 ms 0.961 ms *[Islamabad]* 4 * * * 5 static.khi77.pie.net.pk (221.120.202.13) 23.613 ms 23.488 ms 23.486 ms *[Rawalpindi]* 6 static-10GE-KHI494-P01-KHI494-SWA.pie.net.pk (202.125.128.174) 23.985 ms 23.854 ms 23.727 ms 7 221.120.254.5 24.049 ms 23.802 ms 23.800 ms *[Rawalpindi]* 8 221.120.253.42 26.667 ms 26.426 ms 26.676 ms *[Rawalpindi]* 9 CallTech.rwp44d2.pie.net.pk (202.125.154.162) 27.173 ms 28.175 ms 27.175 ms *[Rawalpindi]* 10 172.31.252.102 (172.31.252.102) 26.925 ms 26.838 ms 26.838 ms *[Peshawar]* 11 * * *
2
Route followed from Agriculture University (Peshawar) to Fast University (Lahore)
3 se11-1-2-1.rwp44d2.pie.net.pk(202.125.154.161) 0.620 ms 0.569 ms 0.490 ms *[Islamabad]* 4 rwp44.pie.net.pk (221.120.253.41) 4.485 ms 3.731 ms 3.613 ms *[Rawalpindi]* 5 rwp44.pie.net.pk (221.120.254.2) 11.358 ms 11.603 ms 11.484 ms *[Rawalpindi]* 6 rwp44.pie.net.pk (221.120.252.226) 10.233 ms 10.229 ms 10.360 ms *[Rawalpindi]* 7 lhr63.pie.net.pk (221.120.216.198) 10.608 ms 10.598 ms 10.609 ms *[Lahore]* 8 172.31.240.38 (172.31.240.38) 11.109 ms 11.104 ms 11.108 ms *[Lahore]* 9 172.31.252.230 (172.31.252.230) 10.865 ms 10.829 ms 10.732 ms *[Lahore]* 10 lhr-nu.edu.pk (111.68.102.125) 10.983 ms 10.976 ms 10.985 ms *[Lahore]*
3
Route followed from Fast University (Lahore) to Agriculture University (Peshawar)
1 lhr-nu.edu.pk (111.68.102.113) 0.346 ms 0.443 ms 0.453 ms *[Lahore]* 2 172.31.252.229 (172.31.252.229) 0.559 ms 0.839 ms 0.882 ms 3 172.31.240.37 (172.31.240.37) 0.741 ms 1.013 ms 1.067 ms 4 lhr63.pie.net.pk (221.120.216.197) 0.570 ms 0.585 ms 0.556 ms *[Lahore]* 5 (221.120.252.225) 2.528 ms 2.512 ms 2.498 ms *[Rawalpindi]* 6 rwp44.pie.net.pk (221.120.254.1) 10.315 ms 10.332 ms 10.310 ms *[Rawalpindi]* 7 rwp44.pie.net.pk (221.120.253.214) 10.817 ms 10.894 ms 10.907 ms *[Rawalpindi]* 8 CallTech.rwp44d2.pie.net.pk(202.125.154.162) 11.071 ms 11.341 ms 11.345 ms *[Islamabad]* 9 172.31.252.94 (172.31.252.94) 22.935 ms 22.969 ms 22.976 ms 10 121.52.148.245.pern.pk (121.52.148.245) 11.054 ms 11.005 ms 11.109 ms *[Islamabad]*
4
traceroute from pinger.seecs.edu.pk (Islamabad) to npm.neduet.edu.pk (Karachi)
1 115-186-131-65.nayatel.pk (115.186.131.65) 0.730 ms 0.635 ms 0.701 ms 2 115-186-128-177.nayatel.pk (115.186.128.177) 0.800 ms 0.749 ms 0.962 ms *[Islamabad]* 3 58-65-175-2.nayatel.pk (58.65.175.2) 1.178 ms 0.919 ms 0.915 ms *[Islamabad]* 4 * * * 5 static.khi77.pie.net.pk (221.120.202.13) 24.410 ms 24.308 ms 24.180 ms *[Rawalpindi]* 6 static-10GE-KHI494-P01-KHI494-SWB.pie.net.pk (202.125.128.157) 24.551 ms 24.426 ms 24.760 ms 7 221.120.251.22 25.156 ms 24.704 ms 32.002 ms *[Rawalpindi]* 8 khi77.pie.net.pk (221.120.205.98) 24.790 ms 24.093 ms khi77.pie.net.pk (202.125.134.242) 24.416 ms 9 172.31.240.66 (172.31.240.66) 28.057 ms 27.707 ms 25.432 ms *[Karachi]* 10 172.31.253.46 (172.31.253.46) 24.617 ms 24.417 ms 24.291 ms *[Karachi]*