List of things to do:

  • Start QNAP NAS (in S20 gallery) and ask Ken/Jeremy to mount it on all facet computers (facet-srv20, cpu-liXX-pmXX)
  • Test DAQ
  • Check pico motor servers are running
  • Check state of flippers. They might have gone to an unsafe state.
  • Home UPX stages. Do this only for stages you know are safe to move.
  • Test transmission through IP with alignment laser. The oven mover, actuators with foils or wire scanners may be in an undefined state.


Things to check:3/2/24 outageSystem owner:Notes:




Oven mover is in bypass position


Doug S.Required to clear MPS fault.
Retract the DS Be window 
Doug S. / Ivan
PB, spectrometer, and laser transport turbos on
Doug S. / Ivan
When LCW is off: Ensure beamline valves inserted, DPS turbos and roughing pumps are OFF.
Doug S.

When LCW is back on: DPS pumps restarted (US and DS turbos and roughing pumps).

  • VV 3172 retracted when vacuum is stable.

Ops / Doug S.DS Be window should be retracted first
DPS Vacuum watcher restarted
Ops / Doug S.
Spectrometer Camera Checkout Procedure
Doug S.
IP flippers are checked and are in a safe state


Motor reinitialisation: Most motors are homed, a few are postponed to next PAMM (see: here)


Alignment laser can transmit through IP into IPTOR1. IPOTR2 → Camera problems, DSOTR→ Motor issues (catered)