OAP swap (24th April 2024)



During the PAMM of the 24th of April 2024 we exchanged the focusing optic of the collider laser arm from a gold-coated off-axis parabola to a dielectric one. A summary of the procedure can be found here: Picnic Basket.

This is to evaluate the efficacy of this swap:



Assumptions:
Laser pulse length48 fs FWHM
Energy post main amplifier600 mJ
Energy on target228 mJ



Focal quality comparison before and after swap during PAMM


Dataset E320_07259Focal scan during PAMM gold OAP (04/23/24)

                             

E320_07261 Focal scan during PAMM dielectric OAP (04/25/24)

                      




Focal quality comparing beamtime prior and post OAP swap

E320_05518Focal scan beamtime gold OAP (02/18/24)

                         





E320_07492 Focal scan beamtime dielectric OAP (05/01/2024)

                            