Look also at

Troubleshooting Guides

How to access cameras via the FACET control system

  • start "facethome" on a facet control server
  • select "Physics Apps", then "Profile monitor" (wait for some time)
  • select the camera name (order is "random") and press "start" (button is where it says "stop" in the screen shot)
  • select "bit depth" to adjust the intensity scale
  • click "zoom" to zoom in the picture

Open the status overview / settings for all cameras ("PyDM all cameras")

Read cameras via python

Overview

Types:

CameraChipPixel SizeNumber of PixelADCFPSPeak QEDark noiseSaturation capacityURL

Manta G-895

 
Sony IMX2673.45 µm

4112 (H) × 2176 (V)
(14.2 mm x 7.5 mm)

12 Bit13.465%2.1e-10500 e-AVT homepage
datasheet

Mako G-125

Sony ICX4453.75 µm1292 (H) × 964 (V)
(4.8 mm x 3.6 mm)
14 Bit3055%

AVT homepage

Alvium 1800 U-1240

Sony IMX226

1.85 µm


4024 (H) × 3036 (V)
(7.4 mm x 5.6 mm)
10 Bit35


AVT homepage
Alvium 1800 U-120m
3.75 µm1280 (H) × 960 (V)
(4.8 mm x 3.6 mm)
12 Bit52


AVT homepage

Allied Vision Cameras

Camera_and_Driver_Attributes.pdf
Manta_TechMan.pdf

Noise and gain

  • The gain is usually set to zero


Change settings: binning, exposure time

facethome → Profile Monitor → LI20 → PYDM All Cameras → Advanced →

Acquire camera data

Facethome → Matlab GUI → Profile monitor


Get Information about the cameras in EPICS

Troubleshooting

Camera is updating, but not showing data

Wrong event code



  • No labels