LCLS LLRF Screenshots at start of Fall 2013 Downtime
LCLS LLRF Linac Upgrade Screenshots on April 7th 2014
LCLS LLRF MAC addresses (web page view)
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
IOC name | Description | RTEMS VER | EPICS BASE VER | APP SW VER | udpComm | Non-udpComm | Feedback | Non-Feedback | MCAST GROUP | STATION NUM |
ioc-in20-rf01 | Master IOC RF01 in IN20 (Main) | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Llrf4-R1-7-2-BR-4-0 |
|
|
|
|
|
|
ioc-in20-rf02 | Master IOC RF02 (Coherent Lsr) | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | LLRF/Upgrades/Coherent_laser/llrf4_Coherent_Laser |
|
|
|
|
|
|
ioc-in20-rf03 | Master IOC RF03 (Diagnostics) | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 |
|
|
|
|
|
|
ioc-in20-rf04 | Master IOC RF04 (TCAV0) | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 |
|
|
|
|
|
|
ioc-li24-rf01 | Master IOC in LI24 (Main) | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 |
LLRF/Llrf4-R1-7-2-BR-8-0 |
|
|
|
|
|
|
ioc-li24-rf02 | Master IOC RF02 (Diagnostics) | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 |
Not booted. Unused. |
|
|
|
|
|
|
ioc-dmp1-rf01 | Master IOC RF01 in DMP1 (XTCAV) | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 |
|
|
|
|
|
|
eioc-in20-rd01 | Main Drive Line/Reference PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad-R3-3-0 |
| V | V |
|
|
|
eioc-in20-rd02 | Thales Laser PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad6-R1-3-0 | V |
|
| V | IOC-IN20-RF01-PADG | 1 |
eioc-in20-rd03 | Gun1 PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad6-R1-3-0 | V |
|
| V | IOC-IN20-RF01-PADG | 2 |
eioc-in20-rd04 | Gun2 PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad-R3-2-0 |
| V |
| V |
|
|
eioc-in20-rd05 | Klystron 20-6 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 4 |
eioc-in20-rd06 | L0A/L0B PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad6-R1-3-0 | V |
| V |
| IOC-IN20-RF01-PADG | 3 |
eioc-in20-rd07 | Klystron 20-7 Diagnositcs PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 5 |
eioc-in20-rd08 | Klystron 20-8 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 6 |
eioc-in20-rd09 | TCAV0 PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
| V |
| IOC-IN20-RF01-PADG | 7 |
eioc-in20-rd10 | Klystron 20-5 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 3 |
eioc-in20-rd11 | L1S PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad6-R1-3-0 | V |
| V |
| IOC-IN20-RF01-PADG | 5 |
eioc-in20-rd12 | Klystron 21-1 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 1 |
eioc-in20-rd13 | PCAV1/PCAV2 PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 |
LLRF/Pad6-R1-3-0-PH1PH2 | V |
|
| V |
IOC-LI24-RF01 | 9 |
eioc-in20-rd14 | L1X PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pad6-R1-3-0 | V |
| V |
| IOC-IN20-RF01-PADG | 6 |
eioc-in20-rd15 | Klystron 21-2 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 7 |
eioc-in20-rd16 | Coherent Laser PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | LLRF/Upgrades/pad6 | V |
|
| V | IOC-IN20-RF02-PADG | 1 |
eioc-in20-rd17 | 476MHz Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-3 | V |
|
| V | IOC-IN20-RF03-PADG | 2 |
eioc-li24-rd01 | TCAV3 PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pad6-R1-3-0 | V |
| V |
| IOC-LI24-RF01-PADG | 8 |
eioc-li24-rd02 | Klystron 24-8 Diagnostics/PCAV3 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pad6-R1-3-0 | V |
|
| V | IOC-LI24-RF01-PADG | 11 |
eioc-li24-rd03 | Klystron 24-5 Diagnostics PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 |
LLRF6/llrf6/Llrf6-R3-2-0 | V |
|
| V | IOC-LI24-RF02-PADG | 1 |
eioc-li29-rd01 | PCAV4 PAD | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pad6-R1-3-0 | V |
|
| V | IOC-LI24-RF01-PADG | 12 |
eioc-dmp1-rd01 | XTCAV PAD1 | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
| V |
| IOC-DMP1-RF01-PADG | 1 |
eioc-dmp1-rd02 | XTCAV PAD2 | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
|
| V | IOC-DMP1-RF01-PADG | 2 |
eioc-dmp1-rd03 | XTCAV KLY Diag PAD | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
|
| V | IOC-DMP1-RF01-PADG | 3 |
eioc-in20-rc01 | Reference SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac-R5-2-0 |
| V | V (FastFeedbak) |
|
|
|
eioc-in20-rc02 | MDL SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac-R5-2-0 |
| V | V (FastFeedbak) |
|
|
|
eioc-in20-rc03 | LCL SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac-R5-2-0 |
| V |
| V |
|
|
eioc-in20-rc04 | CLK SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac-R5-2-0 |
| V |
| V |
|
|
eioc-in20-rc05 | Thales Laser SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-0 | V |
|
| V (Local FB) | IOC-IN20-RF01-PACG | 1 |
eioc-in20-rc06 | Gun PAC 20-6 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-0 | V |
|
| V (Local FB) | IOC-IN20-RF01-PACG | 2 |
eioc-in20-rc07 | L0A PAC 20-7 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-0 | V |
| V (Local + FF) |
| IOC-IN20-RF01-PACG | 3 |
eioc-in20-rc08 | L0B PAC 20-8 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-0 | V |
| V (Local + FF) |
| IOC-IN20-RF01-PACG | 4 |
eioc-in20-rc09 | TC0 PAC 20-5 | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
|
| V (Local FB) | IOC-IN20-RF01-PACG | 7 |
eioc-in20-rc10 | L2 SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-1 | V |
| V (FastFeedbak) |
| IOC-IN20-RF01-PACG | 18 |
eioc-in20-rc11 | L1S PAC 21-1 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-2 | V |
| V (Local + FF) |
| IOC-IN20-RF01-PACG | 5 |
eioc-in20-rc12 | L1X PAC 21-2 | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | Pac2-R1-0-0 | V |
| V (Local + FF) |
| IOC-IN20-RF01-PACG | 6 |
eioc-in20-rc13 | Coherent Laser SPAC | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | LLRF/Upgrades/pac2 | V |
|
| V (Local FB) | IOC-IN20-RF02-PACG | 1 |
eioc-li24-rc01 | KLY 24-1 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
| V (FastFeedbak) |
| IOC-LI24-RF01-PACG | 13 |
eioc-li24-rc02 | KLY 24-2 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
| V (FastFeedbak) |
| IOC-LI24-RF01-PACG | 14 |
eioc-li24-rc03 | KLY 24-3 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
| V (FastFeedbak) | V (change to FF) | IOC-LI24-RF01-PACG | 15 |
eioc-li24-rc04 | TCAV3 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
|
| V (Local FB) | IOC-LI24-RF01-PACG | 8 |
eioc-li24-rc05 | S24 SPAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac-R5-2-0 |
| V |
| V |
|
|
eioc-li24-rc07 | KLY 24-5 PAC | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | LLRF6/Llrf6-R3-0-1 |
| V |
| V |
|
|
eioc-li29-rc01 | S29 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
| V (FastFeedbak) |
| IOC-LI24-RF01-PACG | 16 |
eioc-li30-rc01 | S30 PAC | RTEMS-4.9.4-slac_p1 | EPICS R3.14.8.2-LCLS_5 | LLRF/Pac2-R1-0-0 | V |
| V (FastFeedbak) |
| IOC-LI24-RF01-PACG | 17 |
eioc-dmp1-rc01 | XTCAV PAC | RTEMS-4.9.4-slac_p0 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-1-5 | V |
|
| V (Local FB) | IOC-DMP1-RF01-PACG | 1 |
sioc-sys0-rf01 | L2/L3 Phase Control | Linux 2.6.18-274.18.1.el5PAE i686 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-0-7 |
|
| V (FastFeedbak) |
|
| |
sioc-sys0-rf02 | PCAV/PAU-Mux Alarms | Linux 2.6.18-274.18.1.el5PAE i686 | EPICS R3.14.12-SLAC_2 | Llrf6-R3-0-8 |
|
|
|
|
| |
sioc-in20-rf01 | Diagnostics softLlrf | Linux 2.6.18-274.18.1.el5PAE i686 | EPICS R3.14.12-SLAC_2 | Llrf6-R2-2-0 |
|
|
|
|
| |
sioc-dmp1-rf01 | XTCAV MKSUII Soft IOC | Linux 2.6.18-274.18.1 | EPICS R3.14.12-SLAC_2 | LLRF6/llrf6/MAIN_TRUNK |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|