IOC name

Description

EPICS BASE VER

APP SW VER

udpComm

Non-udpComm

Feedback

Non-Feedback

MCAST GROUP

STATION NUM

ioc-in20-rf01

Master IOC RF01 in IN20  (Main)

R3-14-8-2-lcls6

Llrf4-R1-7-3

 

 

 

 

 

 

ioc-in20-rf02

Master IOC RF02  (Coherent Lsr)

R3-14-12

Llrf4-R1-7-4

 

 

 

 

 

 

ioc-in20-rf03

Master IOC RF03 (Diagnostics)

R3-14-12

Llrf6-R2-1-0

 

 

 

 

 

 

ioc-li24-rf01

Master IOC in LI24 (Main)

R3-14-8-2-lcls6

Llrf4-R1-7-3

 

 

 

 

 

 

ioc-li24-rf02

Master IOC RF02 (Diagnostics)

R3-14-12

Llrf6-R2-1-0

 

 

 

 

 

 

eioc-in20-rp01

Phase Lock Loop

R3-14-12

Pll-R2-2-0

 

V

 

 

 

 

eioc-in20-rd01

Main Drive Line/Reference PAD

R3-14-8-2-lcls6

Pad-R3-3-0

 

V

V

 

 

 

eioc-in20-rd02

Thales Laser PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

 

V

IOC-IN20-RF01-PADG

1

eioc-in20-rd03

Gun1 PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

 

V

IOC-IN20-RF01-PADG

2

eioc-in20-rd04

Gun2 PAD

R3-14-8-2-lcls6

Pad-R3-2-0

 

V

 

V

 

 

eioc-in20-rd05

Klystron 20-6 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

4

eioc-in20-rd06

L0A/L0B PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

V

 

IOC-IN20-RF01-PADG

3

eioc-in20-rd07

Klystron 20-7 Diagnositcs PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

5

eioc-in20-rd08

Klystron 20-8 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

6

eioc-in20-rd09

TCAV0 PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

V

 

IOC-IN20-RF01-PADG

7

eioc-in20-rd10

Klystron 20-5 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

3

eioc-in20-rd11

L1S PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

V

 

IOC-IN20-RF01-PADG

5

eioc-in20-rd12

Klystron 21-1 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

1

eioc-in20-rd13

PCAV1/PCAV2 PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

 

V

IOC-IN20-RF01-PADG

9

eioc-in20-rd14

L1X PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

V

 

IOC-IN20-RF01-PADG

6

eioc-in20-rd15

Klystron 21-2 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

7

eioc-in20-rd16

Coherent Laser PAD

R3-14-12

Pad6-R1-4-0

V

 

 

V

IOC-IN20-RF02-PADG

1

eioc-in20-rd17

476MHz Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-IN20-RF03-PADG

2

eioc-li24-rd01

TCAV3 PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

V

 

IOC-LI24-RF01-PADG

8

eioc-li24-rd02

Klystron 24-8 Diagnostics/PCAV3

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

 

V

IOC-LI24-RF01-PADG

11

eioc-li24-rd03

Klystron 24-5 Diagnostics PAD

R3-14-12

Llrf6-R2-1-0

V

 

 

V

IOC-LI24-RF02-PADG

1

eioc-li29-rd01

PCAV4 PAD

R3-14-8-2-lcls6

Pad6-R1-3-0

V

 

 

V

IOC-IN20-RF01-PADG

12

eioc-in20-rc01

Reference SPAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

V (FastFeedbak)

 

 

 

eioc-in20-rc02

MDL SPAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

V (FastFeedbak)

 

 

 

eioc-in20-rc03

LCL SPAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

 

V

 

 

eioc-in20-rc04

CLK SPAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

 

V

 

 

eioc-in20-rc05

Thales Laser SPAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

 

V (Local FB)

IOC-IN20-RF01-PACG

1

eioc-in20-rc06

Gun PAC 20-6

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

 

V (Local FB)

IOC-IN20-RF01-PACG

2

eioc-in20-rc07

L0A PAC 20-7

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (Local + FF)

 

IOC-IN20-RF01-PACG

3

eioc-in20-rc08

L0B PAC 20-8

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (Local + FF)

 

IOC-IN20-RF01-PACG

4

eioc-in20-rc09

TC0 PAC 20-5

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

 

V (Local FB)

IOC-IN20-RF01-PACG

7

eioc-in20-rc10

L2 SPAC

R3-14-8-2-lcls6

Pac2-R1-0-1

V

 

V (FastFeedbak)

 

IOC-IN20-RF01-PACG

18

eioc-in20-rc11

L1S PAC 21-1

R3-14-8-2-lcls6

Pac2-R1-0-2

V

 

V (Local + FF)

 

IOC-IN20-RF01-PACG

5

eioc-in20-rc12

L1X PAC 21-2

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (Local + FF)

 

IOC-IN20-RF01-PACG

6

eioc-in20-rc13

Coherent Laser SPAC

R3-14-12

Pac2-R1-1-0

V

 

 

V (Local FB)

IOC-IN20-RF02-PACG

1

eioc-li24-rc01

KLY 24-1 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (FastFeedbak)

 

IOC-LI24-RF01-PACG

13

eioc-li24-rc02

KLY 24-2 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (FastFeedbak)

 

IOC-LI24-RF01-PACG

14

eioc-li24-rc03

KLY 24-3 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (FastFeedbak)

V (change to FF)

IOC-LI24-RF01-PACG

15

eioc-li24-rc04

TCAV3 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

 

V (Local FB)

IOC-LI24-RF01-PACG

8

eioc-li24-rc05

S24 SPAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

 

V

 

 

eioc-li24-rc07

KLY 24-5 PAC

R3-14-8-2-lcls6

Pac-R5-2-0

 

V

 

V

 

 

eioc-li29-rc01

S29 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (FastFeedbak)

 

IOC-LI24-RF01-PACG

16

eioc-li30-rc01

S30 PAC

R3-14-8-2-lcls6

Pac2-R1-0-0

V

 

V (FastFeedbak)

 

IOC-LI24-RF01-PACG

17

 

 

 

 

 

 

 

 

 

 

  • No labels