Contents:

Shelves

ID

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Date

Notes

Shasta

COB 2-1

X

 

 

COB 2-2

120606

 

Freel

COB 2-3

X

 

 

COB 3-2

120607

 

Olancha

 

X

 

 

COB 3-4

120607

 

Keynot

 

X

 

 

COB 3-1

120607

 

Darwin

 

X

 

 

 

120607

At BNL or Penn

Ritter

 

X

 

 

COB 3-5

120607

At BNL or Penn

Whitney

 

 

 

 

 

 

14 slots

COBs

V4 JTAG switch settings

Value

Device

0000

Base

0001

DPM-0

0010

DPM-1

0011

DPM-2

0100

DPM-3

0101

DTM

Inventory

ID

Site 0

Site 1

Site 2

Site 3

Site 4

Date

Notes

2-1

 

 

 

 

 

120605

Back from JLAB 120525 – switch broken 120605

2-2

DTM 2-7

 

DPM 2-2

 

DPM 2-7

120605

Back from JLAB 120525,
green health LED not lighting (120605); Fixed (120606)

2-3

DTM 2-8

 

DPM 4

 

 

120605

 

3-1

DTM 2-6

 

DPM 2-6

 

 

120503

Blue LED doesn't light (120605); Fixed (120606)

3-2

DTM 2-3

 

DPM 2-1

 

 

120607

 

3-4

DTM 2-2

 

DPM 2-12

 

 

120605

 

3-5

DTM 2-4

 

DPM 2-5

 

 

120605

 

DTM405s

ID

Serial No.

MAC

Firmware

EEPROM

System 0

System 1

Date

Notes

1-2

 

 

 

 

 

 

 

Bad. DO NOT USE.

2-1

 

08:00:56:00:41:38

868

0.8.0

prod 2.2, 8??

rescue 2.2, 8xx

2012-05-02

With Ryan for Heavy Photon

2-2

000000445F63

08:00:56:00:41:32

868

0.8.0

prod 2.2, 927M

rescue 2.2, 927M

2012-05-03

OK

2-3

00000044895C

08:00:56:00:41:33

868

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

120607

Filed down power connectors: don't screw down front side

2-4

000000445FC5

08:00:56:00:41:34

868

 

prod 2.2, 927M

rescue 2.2, 927M

2012-05-03

OK

2-5

 

 

868

0.8.0

prod 2.2, 927M

rescue 2.2, 927M

2012-05-02

EEPROM Read errors; Disrupts JTAG to the DPMs

2-6

000000445D84

08:00:56:00:41:36

868

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

 

 

2-7

00000044555C

08:00:56:00:43:06

868

 

 

 

 

 

2-8

000000445F63

08:00:56:00:41:38

868

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

2012-05-31

 

DPM 405s

ID

Ser. No.

MAC

Firmware

EEPROM

System 0

System 1

Date

Notes

2-1

000000197519

08:00:56:00:42:fc

917

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

120531

OK

2-2

00000019c057

08:00:56:00:42:f7

917

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

120531

OK

2-3

000000197DAD

08:00:56:00:42:f9

917

0.8.0

 

 

120503

Fails: peb 0 exception 0x8baec1 edw 0x5f transferred 0; EEPROM Read errors. XMD gives:

ERROR: Unable to STOP PowerPC Processor
	Check: (1) If the FPGA is Configured Correctly (or)
 	(2) If Processor Reset and Clock Ports are Connected Correctly

C103 scraped off.

2-4

00000019B108

08:00:56:00:42:XX

917

 

prod 2.2, 927M

rescue 2.2, 927M

120503

Programming f/w took two attempts; XMD 'dow'ing devel and 'con'ing causes crash to 0x700. XMD gives:

ERROR: Unable to STOP PowerPC Processor
	Check: (1) If the FPGA is Configured Correctly (or)
 	(2) If Processor Reset and Clock Ports are Connected Correctly

C76 and R22 scraped off.

2-5

00000019A827

08:00:56:00:42:f5

917

0.8.0

prod 2.2, 927M

rescue 2.2, 927M

120503

OK

2-6

00000019C145

08:00:56:00:42:fa

917

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

120531

OK

2-7

00000019D013

08:00:56:00:42:f8

917

 

prod 2.2, 1088:1104

rescue 2.2, 1088:1104

120531

OK

2-8

000000196E67

 

 

 

 

 

 

Bad. XMD gives:

ERROR: Unable to STOP PowerPC Processor
	Check: (1) If the FPGA is Configured Correctly (or)
 	(2) If Processor Reset and Clock Ports are Connected Correctly

2-9

 

08:00:56:00:42:f4

917

 

prod 2.2, 927M

rescue 2.2, 927M

120503

OK

2-10

00000019DC05

08:00:56:00:42:fb

917

 

prod 2.2, 927M

rescue 2.2, 927M

120503

OK

2-11

000000197D2F

08:00:56:00:42:XX

 

 

 

 

120503

Mark says board is bad. XMD gives:

ERROR: Unable to STOP PowerPC Processor
	Check: (1) If the FPGA is Configured Correctly (or)
 	(2) If Processor Reset and Clock Ports are Connected Correctly

2-12

000000198C40

08:00:56:00:42:f6

917

 

prod 2.2, 927M

rescue 2.2, 927M

120503

OK

DPM 440s

ID

Ser. no.

MAC

Firmware

MemTest

EEPROM

System 0

System 1

Date

Notes

02

000000457EXX

08:00:56:00:43:XX

DpmTest_DB0000XX

 

 

 

 

 

 

03

000000457EXX

08:00:56:00:43:XX

DpmTest_DB0000XX

 

 

 

 

 

 

04

000000457E18

08:00:56:00:43:01

DpmTest_DB000018

Passed

 

 

 

120529

@ Bruce

06

000000459BCC

08:00:56:00:43:0e

DpmTest_DB000018

Passed

 

 

 

120529

 

07

00000045403A

08:00:56:00:43:00

DpmTest_DB000018

Passed

 

 

 

120529

 

08

000000457EXX

08:00:56:00:43:XX

DpmTest_DB0000XX

 

 

 

 

 

 

09

0000004538B3

08:00:56:00:43:04

DpmTest_DB000018

Won't load

 

 

 

120530

impact works, xmd doesn't

12

000000455233

08:00:56:00:43:0d

DpmTest_DB000018

Passed

 

 

 

120530

 

13

000000457EXX

08:00:56:00:43:XX

DpmTest_DB0000XX

 

 

 

 

 

 

14

000000456FB5

08:00:56:00:43:03

DpmTest_DB000018

Passed

 

 

 

120530

 

DTM Zynqs

ID

Ser. no.

MAC

MemTest

Network

Date

Notes

01

 

08:00:56:00:43:1C

Not Tested

Passed

130918

 

02

 

08:00:56:00:43:17

Not Tested

Passed

130918

 

03

 

08:00:56:00:43:14

Not Tested

Passed

130918

 

DPM Zynqs

ID

Ser. no.

MAC

MemTest

Network

Date

Notes

01-0

 

08:00:56:00:43:15

Failed

Not Tested

130918

 

01-2

 

08:00:56:00:43:16

Failed

Not Tested

130918

 

02-0

 

08:00:56:00:43:18

Passed

Passed

130918

 

02-2

 

08:00:56:00:43:19

Won't load

Not Tested

130918

 

03-0

 

08:00:56:00:43:1A

Failed

Not Tested

130918

 

03-2

 

08:00:56:00:43:1B

Passed

Failed

130918

 

RTMs

Type

Ser. no.

EEPROM

Date

Notes

Old

2-1

 

1205xx

 

Old

2-2

 

1205xx

 

STP

00000063488A

 

120607

 

STP

00000044C85C

 

120607

 

STP

0000006362BE

 

120607

 

STP

00000044BB35

 

120607

 

STP

00000044C289

 

120607

 

STP

000000450F2F

 

120607

 

STP

00000044BE81

 

120607

 

SNAP-12

000000474DE0

 

120607

 

SNAP-12

000000632FD9

 

120607

 

SNAP-12

000000

 

 

 

SNAP-12

000000

 

 

 

SNAP-12

000000

 

 

 

SNAP-12

000000

 

 

 

SNAP-12

000000

 

 

 

Experimental HW database dump (see The COB board database in Oracle)

COB modules

Supertype

Type

Serial no.

MAC Addr

Good?

Retired?

Comment

rtm

snap-12

000000474de0

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#04.

rtm

snap-12

000000632e76

 

(tick)

 

2012-06-14 17:02:12 LEDs OK.
2012-06-14 17:02:12 EEPROM written. SN#05.

rtm

snap-12

000000632fd9

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#03.

rtm

snap-12

000000633007

 

(tick)

 

2012-06-14 17:19:57 LEDs OK.
2012-06-14 17:19:57 EEPROM written. SN#08.

rtm

snap-12

0000006362e9

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#02.

rtm

snap-12

0000006362f4

 

(tick)

 

2012-08-29 18:39:06 EEPROM written. Backwards I2C chip reinstalled.
2012-08-29 18:39:06 LEDs OK.

rtm

snap-12

000000637191

 

(tick)

 

2012-06-14 17:07:38 LEDs OK.
2012-06-14 17:07:38 EEPROM written. SN#06.

rtm

sfp

00000044bb35

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#06.

rtm

sfp

00000044be81

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#08.

rtm

sfp

00000044c289

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#05.

rtm

sfp

00000044c85c

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#07.

rtm

sfp

000000450f2f

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#03.

rtm

sfp

00000063488a

 

(tick)

 

2012-05-02 00:31:47 EEPROM written. SN#02.

rtm

sfp

0000006362be

 

(tick)

 

2012-06-07 14:00:00 EEPROM written. SN#04.

cmb1

dpm405

000000196e67

080056004308

(error)

 

2012-05-02 00:31:47 EEPROM written. REV-2-08.
2012-06-05 22:14:00 XMD unable to stop processor.

cmb1

dpm405

000000197519

0800560042fc

(tick)

 

2012-05-02 00:31:47 EEPROM written. 2-1.
2012-05-31 00:00:00 Firmware 917.
2012-05-31 00:00:00 Sys images 0: prod 2.2 SVN 1088:1104, 1: rescue ditto

cmb1

dpm405

000000197d2f

080056004307

(error)

 

2012-05-02 00:31:47 XMD unable to stop processor.
2012-05-02 00:31:47 EEPROM written. REV-2-11.

cmb1

dpm405

000000197dad

0800560042f9

(error)

 

2012-05-31 00:00:00 Firmware 917. EEPRPM 0.8.0.
2012-06-02 00:31:47 EEPROM written. REV-2-03.
2012-06-05 22:14:00 PEB 0 exception 0x8baec1 edw 0x5f.
2012-06-05 22:14:00 C103 has been scraped off.
2012-06-05 22:14:00 XMD unable to stop processor.
2012-06-05 22:14:00 EEPROM read errors.

cmb1

dpm405

000000198c40

0800560042f6

(error)

 

2012-05-02 00:31:47 EEPROM written. 2-12.
2012-05-03 00:00:00 Firmware 917.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-12-08 00:54:26 Good 1 -> 0.
2012-12-08 00:54:26 memTest fails within first MB

cmb1

dpm405

00000019a827

0800560042f5

(tick)

 

2012-05-02 00:31:47 EEPROM written. REV-2-05.
2012-05-03 00:00:00 Firmware 917. EEPROM 0.8.0.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.

cmb1

dpm405

00000019b108

0800560042f2

(error)

 

2012-05-02 00:31:47 EEPROM written. 2-04.
2012-05-03 00:00:00 Firmware 917.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-05-03 00:31:47 Programming firmware took two attempts.
2012-05-03 00:31:47 XMD: "con" after "dow" caused crash at 0x700.
2012-05-03 22:14:00 XMD unable to stop processor.
2012-05-03 22:14:00 C76 and R22 have been scraped off.

cmb1

dpm405

00000019bbb3

0800560042f4

(tick)

 

2012-05-02 00:31:47 EEPROM written. 2-09.
2012-05-03 00:00:00 Firmware 917.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.

cmb1

dpm405

00000019c145

0800560042fa

(tick)

 

2012-05-02 00:31:47 EEPROM written. 2-06.
2012-05-31 00:00:00 Firmware 917.
2012-05-31 00:00:00 Sys images: 0: prod 2.2 SVN 1088:1104, 1: rescue ditto.

cmb1

dpm405

00000019cd57

0800560042f7

(tick)

 

2012-05-02 00:31:47 EEPROM written. REV-2-02.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 1088:1104, 1: rescue ditto
2012-05-03 00:00:00 Firmware 917.

cmb1

dpm405

00000019d013

0800560042f8

(tick)

 

2012-05-02 00:31:47 EEPROM written. 2-07.
2012-05-03 00:00:00 Firmware 917.
2012-05-03 00:00:00 Sys images: 0: prod 2.2 SVN 1088:1104, 1: rescue ditto.

cmb1

dpm405

00000019dc05

0800560042fb

(tick)

 

2012-05-02 00:31:47 EEPROM written. 2-10.
2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-05-03 00:00:00 Firmware 917.

cmb1

dpm440

0000004538b3

080056004304

(error)

 

2012-05-30 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN009.
2012-06-05 22:14:00 Impact works, xmd doesn't. Can't load MemTest.
2012-11-19 23:01:42 EEPROM modified. Change the first port from xaui to 1000basex_lane0

cmb1

dpm440

00000045403a

080056004300

(tick)

 

2012-05-29 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN*07.
2012-08-09 19:37:39 MGT voltage changed from 1.2V to 1.0V.
2012-08-09 19:37:44 SD rework done.
2012-08-09 19:42:03 Has Matt's DTM fixes.

cmb1

dpm440

000000454296

080056004309

(tick)

 

2012-08-08 23:17:29 EEPROM written. SN#2. From Ryan.
2012-08-08 23:23:18 MGT voltage changed from 1.2V to 1.0V.
2012-08-08 23:23:43 SD rework done.
2012-09-13 21:35:31 EEPROM modified. Configured eth port 0 as 1000basex_lane0.

cmb1

dpm440

000000454f4f

08005600430b

(tick)

 

2012-08-08 23:32:58 EEPROM written. SN#8. From Ryan.
2012-08-08 23:33:12 MGT voltage changed from 1.2V to 1.0V.
2012-08-08 23:33:17 SD rework done.
2012-09-13 21:45:19 EEPROM modified. Configured eth port 0 as 1000basex_lane0.

cmb1

dpm440

000000454f52

08005600430a

(tick)

 

2012-08-08 23:26:31 EEPROM written. SN#3. From Ryan.
2012-08-08 23:26:40 MGT voltage changed from 1.2V to 1.0V.
2012-08-08 23:26:56 SD rework done.

cmb1

dpm440

000000455233

08005600430d

(tick)

 

2012-05-30 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN012.
2012-09-12 18:03:52 Altered EEPROM setting for port 0 ethernet to 1000basex_lane0.
2012-09-12 18:06:11 Altered firmware yesterday to DpmTest_DB00002B.

cmb1

dpm440

000000456fb5

080056004303

(tick)

 

2012-05-30 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN014.
2012-09-13 21:48:10 EEPROM modified. Configured eth port 0 as 1000basex_lane0.

cmb1

dpm440

00000045788e

08005600430c

(tick)

 

2012-08-09 23:22:52 EEPROM written. SN013. From Ben Reese.

cmb1

dpm440

000000457e18

080056004301

(tick)

 

2012-05-29 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN#4.

cmb1

dpm440

000000459bcc

08005600430e

(tick)

 

2012-05-29 00:00:00 Firmware DpmTest_DB000018.
2012-06-05 22:14:00 EEPROM written. SN*06.
2012-08-09 19:35:35 MGT voltage changed from 1.2V to 1.0V.
2012-08-09 19:35:54 SD rework done.
2012-09-12 23:17:25 Altered EEPROM setting for port 0 ethernet to 1000basex_lane0.

cmb1

dtm405

000000000000

 

(error)

(sad)

2012-05-06 00:00:00 Broken beyond repair.
2012-05-06 00:00:00 EEPROM written. R2-1.

cmb1

dtm405

000000000001

 

(error)

 

2012-05-02 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-05-02 00:00:00 Firmware 868. EEPROM 0.8.0.
2012-05-06 00:00:00 EEPROM read errors.
2012-05-06 00:00:00 Disrupts JTAG to DPMs.
2012-05-06 00:00:00 EEPROM written. R2-5.

cmb1

dtm405

00000044555c

080056004138

(tick)

 

2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-06-02 00:00:00 Firmware 868, EEPROM 0.8.0.
2012-06-05 22:14:00 From Jefferson Lab.
2012-06-05 22:14:00 EEPROM written. REV-2#8.

cmb1

dtm405

000000445d84

080056004136

(tick)

 

2012-06-05 22:14:00 Firmware 868.
2012-06-05 22:14:00 Sys images 0: prod 2.2 SVN 1088:1104, 1: rescue ditto.
2012-06-05 22:14:00 EEPROM written. REV2#6.

cmb1

dtm405

000000445f63

080056004306

(tick)

 

2012-06-05 22:14:00 EEPROM written. REV-2-7.

cmb1

dtm405

000000445fc5

080056004134

(tick)

 

2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-05-03 00:00:00 Firmware 868.
2012-06-05 22:14:00 EEPROM written. REV2#4.

cmb1

dtm405

00000044810b

080056004132

(tick)

 

2012-05-03 00:00:00 Sys images 0: prod 2.2 SVN 927M, 1: rescue ditto.
2012-05-03 00:00:00 Firmware 868. EEPROM 0.8.0.
2012-06-05 22:14:00 EEPROM written. R2-2.

cmb1

dtm405

00000044895c

080056004133

(tick)

 

2012-06-05 22:14:00 Broken.
2012-06-05 22:14:00 Repaired, filed down power connectors.
2012-06-05 22:14:00 Don't screw down the front.
2012-06-05 22:14:00 EEPROM written. R2-3.
2012-06-07 00:00:00 Firmware 868.
2012-06-07 00:00:00 Sys images 0: prod 2.2 SVN 1088:1104, 1: rescue ditto.

General (non-board) log entries.

2012-06-13 18:00:00 Database schema v2.
2012-06-15 01:04:23 Implemented dump-as-wiki.
2012-06-15 21:22:00 Added firmware and sys-image info. from Confluence page.

  • No labels