TKR

 

 

 

 

 

 

 CAL

 

 

 

 

 

 

 

 

 ACD

 

 

 

 

 Trigger

 

 

 

 

 

 

 

 

 

Strip DAC [range0]

TREQ delay [ticks]

TACK delay [ticks]

GTRC split

Analog Volts AVDDA [Volts]

Analog Volts AVDDB [Volts]

Digital Volts DVDD [Volts]

Trg Mask File

LowE DAC [Mev]

HighE DAC [Mev]

HighE Amp Gain

TREQ delay [ticks]

TACK   delay [ticks]

Zero Suppress DAC [Mev]

Analog Volts [Volts]

Digital Volts [Volts]

Veto DAC [Mip]

CNO DAC [Mip]

TREQ delay [ticks]

TACK delay [ticks]

Zero Suppress DAC [Mip]

TEM Diagn 

Ext

Tkr

Cal Low

Cal High

CNO

ROI

Trigger Lookup Table

 

 

n

n

n

n

1.5

2.65

2.5

None

100

1000

Off

n

n

2

3.3

3.3

0.2

20

n

n

n

Off

 

 

 

 

 

 

 

 

BT1

All nominal, allowed trigger: external

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

n

Yes

No

No

No

No

No

TZ

 

BT2

All nominal, allowed triiger: tkr, cal_lo,cal_hi,
self-trigger 

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

n

No

Yes

Yes

Yes

No

No

TZ

 

BT3

All nominal, allowed triiger:  tkr
self-trigger 

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

n

No

Yes

No

No

No

No

TZ

 

BT4

All nominal, allowed trigger: external,treq +6 ticks

n

8

n

n

n

n

n

n

n

n

n

6

n

n

n

n

n

1

n

n

n

n

Yes

No

No

No

No

No

TZ

 

BT5

All nominal, ext trigger - treq SPS setting +6 ticks

n

5

n

n

n

n

n

n

n

n

n

6

n

n

n

n

n

1

n

n

n

n

Yes

No

No

No

No

No

TZ

BT6

All nominal, ext trigger - treq SPS, TEM diagnostics ON

n

5

n

n

n

n

n

n

n

n

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ

 BT12

BT1 with Zero suppression OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BT13

 B-13 but CAL_LE only in self-trigger and muon gain and FLE=8MeV

n

n

n

n

n

n

n

n

8

n

On

n

n

n

n

n

n

1

n

n

n

On

No

No

Yes

No

No

No

T4

 

BT14

Cosmic muons for calibration with CU : flight settings, 4 range and zero suppress, Cal trigger only

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

On

No

No

Yes

Yes

No

No

TZ4

 

BT15

flight settings  4 range and NO zero suppress, Cal trigger only

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

On

No

No

Yes

Yes

No

No

T4

 

BT16

  BT1 with 4 range 

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT17

  BT1 with 4 range, FHE=500MeV treq +6 ticks

n

8

n

n

n

n

n

n

n

500

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT18

  BT1 with 4 range, FHE=750MeV treq +6 ticks

n

8

n

n

n

n

n

n

n

750

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT19

  BT1 with 4 range, FHE=1000MeV treq +6 ticks

n

8

n

n

n

n

n

n

n

1000

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT20

  BT1 with 4 range, FHE=1500MeV treq +6 ticks

n

8

n

n

n

n

n

n

n

1500

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT21

  BT1 with 4 range, FHE=2000MeV treq +6 ticks

n

8

n

n

n

n

n

n

n

2000

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT22

  BT1 with 4 range, no zero supp. - for pedestals

n

8

n

n

n

n

n

n

n

n

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

T4

 

BT23 

    BT1 with 4 range, no zero supp. - Muon Gain

n

n

n

n

n

n

n

n

n

n

On

n

n

n

n

n

n

n

n

n

n

On

Yes

No

No

No

No

No

T4

 

BT24

  BT1 with 4 range, FHE=500MeV treq for SPS

n

5

n

n

n

n

n

n

n

500

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT25

  BT1 with 4 range, FHE=750MeV treq for SPS

n

5

n

n

n

n

n

n

n

750

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT26

  BT1 with 4 range, FHE=1000MeV treq for SPS

n

5

n

n

n

n

n

n

n

1000

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT27

  BT1 with 4 range, FHE=1500MeV treq for SPS

n

5

n

n

n

n

n

n

n

1500

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT28

  BT1 with 4 range, FHE=2000MeV treq  for SPS

n

5

n

n

n

n

n

n

n

2000

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

TZ4

 

BT29

  BT1 with 4 range, no zero supp. - for pedestals

n

5

n

n

n

n

n

n

n

n

n

6

n

n

n

n

n

1

n

n

n

On

Yes

No

No

No

No

No

T4

 