search
attachments
weblink
advanced
tooltip
Overview
Content Tools
Beam Test January NewsLetter contribution
Simulation highlights
- BT simulations were successfully ported to the Pipeline II environment by Johan; this ensures a consistent platform with other LAT simulations for data generation, archival and storage, which will allow efficient use of the BT data well after launch. A number of test simulations are now available from the data catalog, and any new simulation will be generated using Pipeline II.
- the H4 line simulation was double-checked and updated by Francesco as to extend the simulation up to the last bending magnet in the line. No significant difference was found in the energy distribution
- a comprehensive comparison with EGS5 from David showed very good agreement with Geant4
- scaling variables: we started looking into ways for scaling the MC data to match our data; Johan explored the consequences of changing CAL calibration constants, Luca scaled the ntuple variables and started looking at consequences of the scaling in the event classification, Carmelo showed the consequences of changing the incoming beam energy by the measured discrepancy. We will have further discussions on this topic in the CA-SO workshop in Bari, and plan to agree on a way to implement this
Analysis highlights
- bad position measurements in the CAL were studied by Philippe and Sasha; a possible explanation for these could be event pile-up, but it requires some more analysis to be confirmed
- TKR cuts are being revised in the light of the new variables introduced for the neutral energy events
- LAC thresholds behave in a different way in data and simulation : potentially due to pedestal drift, issue is under investigation