CERN SR1 Setup

Requirements

  
Number of Local Supports to accommodateOne Stave + One Ring
Maximum Dew Point-60 C
Light tightnessany?
Electrical feed-through to connect two LS at the same timeTwo independent or one with internal split box
Cooling feed-through for cold CO2 (-35C) hosesOne in, one out
Environmental sensors w/ interlockHumidity, Temperature, pressure
LS InterlocksInterlock 


Instruments

DescriptionScopeMake 
Infrared cameraThermal QCFLIRWe expect to measure the sensor temperature in the range of -35 to RT. The operating environment is ~ -10 C
Radioactive SourceElectrical QCSLACDefine type and Intensity. We need envelope of containment box and requirement for the handling and operation
Laser InterferometerMechanical QCSTILOptical Pen - STIL OP10000 + CCS PRIMA http://point.stil-sensors.com/?lang=EN

 

QC test (Validation and or Verification)...this link eventually to the QA/QC documents and the requirements document

   
Thermal performancesThermal Figure of Merit; Temperature uniformity on Module or Heater 
Thermo-mechanical DeformationDeformation of the LS under the effect of the cooing 
Electrical IPower Distribution  
Electrical IIdata transmission 
Electrical III
  1. of dead channels
 

 

 

 