LCLS <---> FACET production gateways

Name

Purpose

PVs served

address for gateway clients

host

config/script dirs

start/stop script

LCLS4FACET

serves LCLS PVs to FACET

all PVs, read-only**

172.27.8.31:5070

lcls-daemon2

$TOOLS/gateway/config,script

/etc/init.d/st.gwLCLS4FACET

FACET4LCLS

serves FACET PVs to LCLS

all PVs, read-only**

172.27.72.24:5070

facet-daemon1

$TOOLS/gateway/config,script

/etc/init.d/st.gwFACET4LCLS

  • LCLS4FACET is configured in the default FACET client EPICS_CA_ADDR_LIST. Configuring the gateway in the IOC EPICS_CA_ADDR_LIST must be done on a case-by-case basis.
  • FACET4LCLS is configured in the default LCLS client EPICS_CA_ADDR_LIST. Configuring the gateway in the IOC EPICS_CA_ADDR_LIST must be done on a case-by-case basis.

** note: Specific PVs are sometimes temporarily blocked for various reasons (e.g. to block duplicate PVs across systems)

LCLS and FACET public gateways

Name

Purpose

PVs served

address for gateway clients

host

config/script dirs

start/stop script

LCLSPUB

serves LCLS PVs to the DMZ

all PVs, read-only*

134.79.151.21:5068

lcls-prod01

$TOOLS/gateway/config,script

/etc/init.d/st.gwLCLSPUB

FACETPUB

serves FACET PVs to the DMZ

all PVs, read-only*

134.79.151.21:5063

lcls-prod01

$TOOLS/gateway/config,script

/etc/init.d/st.gwFACETPUB

  • Both public gatways are both configured in the default DMZ client EPICS_CA_ADDR_LIST.

Gateway status display

lclshome/Network Global/"PV Gateway Diagnostics" button

facethome/Network Global/"PV Gateway Diagnostics" button

  • No labels