Working draft of CCB action -
EngineeringModel changes
1) AnalysisNtuple v2r2p4: one line of code changed
JIRA url: http://jira.slac.stanford.edu/browse/GRINF-21
Incorrect initialization of highest triggered layer. I forgot to change this when the layer numbering got turned around, leading to a failure to properly fill GltTower and GltLayer in the ntuple. These quantities are correctly set in the new tag.
2) TkrUtil v3r3p3: one line of code added
Private communication with A. Borgland; this item got fixed before the JIRA was issued.
Bug in calculation of m_towerType. Was set to -1 for all towers.
Now is correctly set to 0-4 depending on the number of exposed faces of the tower. The relevant line of code was inadvertently dropped during a cleanup a few months ago. The only effect currently is that GltType is now correctly set in the ntuple.
3.) RootIo v14r9
JIRA url: http://jira.slac.stanford.edu/browse/CAL-7
Modification to reading and writing reconstruction data, so that 4 range ALLRANGE) mode may have less than 4 readouts
Private communication with Zach. Fewtrell - the latest version of CalRecon reconstructs at most one energy range, but retains the ability to handle up to four.
Have tested this on an example 4-Range LDF file, and processing continued without crashing.
4.) CalXtalResponse v0r2p7
Communication in CALSOFT mailing list:
http://www-glast.stanford.edu/protected/mail/calsoft/0510.html
http://www-glast.stanford.edu/protected/mail/calsoft/0516.html
http://www-glast.stanford.edu/protected/mail/calsoft/0520.html
Separate flight and muon idealMode.xml calibration files are now provided.
Default jobOptions to flight gain with muon. defaultOptions.txt is prettier & has lots of commenting describing different jobOptions.
superseded by CalXtalResponse v0r2p8
Identical to v0r2p7 except that verbose jobOptions descriptions have been moved to customOptions.txt. This reduces logfile verbosity.
5.) CalRecon v5r22p5em1
JIRA url: http://jira.slac.stanford.edu/browse/CAL-7
Fixes problem running MC in TKR-only mode - required modifying CalRecAlg. CalRecon algorithms now exit gracefully if there is no CalDigi data.
The modifications basically involved checking for CalDigis on the TDS and if they are not found, making sure to gracefully exit CAL recon processing on this event, rather than causing the Gaudi job to terminate.
doxygen comments for anything CalResponse related should now be acceptable
6.) calibGenCAL v3r4p4
Replace use of xml package to the new xmlBase package - a minor change primarily for clean up.
p3 - added outlier removal in histograms for ciFit. this gets rid of possible muon coincidence hits during charge injection which can make nasty calibraiton points.
p4 - xml -> xmlBase update. some documentation updates
7.) Added a use of FRED v0r098p1 IExternal
Private email between Richard Dubois, Navid Golpayegani, Anders Borgland, Joanne Bogart and Heather Kelly
IExternal/Fred was not being included in the source code tarball resulting in many CMT warnings - not fatal, but troublesome. Navid pointed out that the EngineeringModel requirements file needs to specify the version of IExternal/Fred so that it would be checked out of CVS properly and included in the tarball.
8) ldfReader v1r11
Completely generalizes reading the RunId from the FITS header - checks
all keywords in the primary header for the string 'RunId ', and
retrieves its value.
This addresses JIRA ROOT-10: http://jira.slac.stanford.edu/browse/ROOT-10
svac changes
1. change EngineeringModelRoot from v1r3p7 to v1r3p11.
Main change is to fix bugs in GltWord
http://jira.slac.stanford.edu/browse/SVAC-2
and TriggerDiagnostic info http://jira.slac.stanford.edu/browse/SVAC-1
For GltWord, Toby changed definition to include GEM word, the EngineeringModelRoot code went out of sync. For triggerDiagnostic info, meaning of diagnostic flag in event summary word was misunderstood.
2. change TestReport from v3r2p4 to v3r2p6 Main change is also to fix the bug in GltWord
http://jira.slac.stanford.edu/browse/SVAC-2
pipeline changes
setup:
new code tag v3r1p2
many changes to svacPlSetup.cshrc to enable pieline changes below change to dbSetup.cshrc, I suspect this has to do with PIT-1
digitization:
new task version v3r1p2
change LSF queue to address SVAC-3
new code tag v3r1p1
change LSF queue to address SVAC-3
http://jira.slac.stanford.edu/browse/SVAC-3
digiReport:
new task version v3r1p2
change to TestReport v3r2p6 to adress SVAC-2 and SVAC-11
http://jira.slac.stanford.edu/browse/SVAC-11
recon:
new task version v3r1p2
address SVAC-7
new code tag v3r1p1
address SVAC-7
http://jira.slac.stanford.edu/browse/SVAC-7
reconReport:
new task version v3r1p2
change to TestReport v3r2p6 to adress SVAC-2 and SVAC-11
new code tag v3r1p1
http://jira.slac.stanford.edu/browse/SVAC-12
svacTuple:
new task version v3r1p2
change LSF queue to adress SVAC-4
change to EngineeringModelRoot v1r3p11 to adress SVAC-1 and SVAC-2 new code tag v3r1p1
change LSF queue to adress SVAC-4
http://jira.slac.stanford.edu/browse/SVAC-4
apps:
TestReport:
new tag v3r2p6
address SVAC-2 and SVAC-11
EngineeringModelRoot:
new tag v1r3p11
adress SVAC-1 and SVAC-2
Code Versions
Engineering Model (sim/recon) v4r060302p8 *** changed ***
System Tests for this version
System Tests Result
FRED version
Pipeline tag
v1r0p2
GRITS tag (web browsing and task configuration)
glast-ground v0r3p4
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)
online/svac (task defs, scripts):
pipeline tasks:
online: v2r0
updateELogDB: v3r1p1
configReport: v3r1p1
digitization: v3r1p2 **changed**
digiReport: v3r1p2 **changed**
recon: v3r1p2 **changed**
reconReport: v3r1p2 **changed**
svacTuple: v3r1p2 **changed**
pipeline code:
updateELogDB v3r1p0
configReport v3r1p0
digitization v3r1p1 **changed**
digiReport v3r1p0
recon v3r1p1 **changed**
reconReport v3r1p1 **changed**
svacTuple v3r1p1 **changed**
setup v3r1p2 **changed**
lib v3r1p1 **changed**
svaconline v3r1p0
Apps that run in pipeline:
eLog: v2r2
ConfigTables: v3r1p3
TestReport: v3r2p6 (digi & recon reports) **changed**
EngineeringModelRoot: v1r3p11 (SVAC tuple) **changed**
Approved: 1 April - Eduardo, Steve, Richard (Bill not available to respond)
1. FSW upgraded versions of python for their own use, not knowing svac was using it; updateElogDB jobs failed. Change to point to old version (2.2) of python.
http://jira.slac.stanford.edu/browse/PIT-1
2. pipeline back end had bug in handling failed jobs. Had omitted a key 'return' in a case switch. 2nd bug was failing to record size of datasets in the database.
Run '1000' in the demodev task proves this release. Its success can be verified using the DEV TaskRunSummary and Dataset Catalog (beta) utilities in the glast-ground web-app.
http://jira.slac.stanford.edu/browse/PIPE-33
http://jira.slac.stanford.edu/browse/PIPE-34
Code Versions
Engineering Model (sim/recon) v4r060302p6
System Tests for this version
System Tests Result
FRED version
Pipeline tag
v1r0p2 *** changed ***
GRITS tag (web browsing and task configuration)
glast-ground v0r3p4
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)
online/svac (task defs, scripts):
pipeline tasks:
online: v2r0
updateELogDB: v3r1p1
configReport: v3r1p1
digitization: v3r1p1
digiReport: v3r1p1
recon: v3r1p1
reconReport: v3r1p1
svacTuple: v3r1p1
pipeline code:
updateELogDB v3r1p0
configReport v3r1p0
digitization v3r1p0
digiReport v3r1p0
recon v3r1p0
reconReport v3r1p0
svacTuple v3r1p0
setup v3r1p1
lib v3r1p0
svaconline v3r1p0
Apps that run in pipeline:
eLog: v2r2 *** changed ***
ConfigTables: v3r1p3
TestReport: v3r2p4 (digi & recon reports)
EngineeringModelRoot: v1r3p7 (SVAC tuple)
Approved: unanimous March 28
A collection of bug fixes and small changes from Matt. These are all listed in jira:
http://jira.slac.stanford.edu/secure/ReleaseNote.jspa?projectId=10150&styleName=Html&version=10223
They have been tested by Tony Johnson.
Code Versions
Engineering Model (sim/recon) v4r060302p6
System Tests for this version
System Tests Result
FRED version
Pipeline tag
v0r0p0
GRITS tag (web browsing and task configuration)
glast-ground v0r3p4 **changed**
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)
online/svac (task defs, scripts):
pipeline code:
online: v2r0
lib: v3r1p0 (code used by more than one Task)
setup: v3r1p0
svac/online: v3r1p0 (SVAC code that runs in Online's Task)
updateELogDB: v3r1p0
configReport: v3r1p0
digitization: v3r1p0
digiReport: v3r1p0
recon: v3r1p0
reconReport: v3r1p0
svacTuple: v3r1p0
Apps that run in pipeline:
eLog: v2r0
ConfigTables: v3r1p3
TestReport: v3r2p4 (digi & recon reports)
EngineeringModelRoot: v1r3p7 (SVAC tuple)
Approved: unanimous 22 March