Note that in this description, time advances down along the page.
Bear in mind as well that this description applies to the Gen 1 design.
Items in square brackets ([]) are optional.
Initial instruction
- Execution after reset starts at
0xfffffffc
- A branch instruction (either
b
orba
; 26 bit range) to some boot code is loaded here- The Xilinx example branches to in block RAM (
bram
) at0xffffff00
- The RTEMS example branches to
download_entry
(but I'm not sure how)
- The Xilinx example branches to in block RAM (
- Potentially a
sc
(system call) instruction could be loaded here? Any advantage to this?- Probably not as the corresponding
ivor
register (PPC 440) is not loaded yet - The PPC 405 doesn't have
ivor
registers, so it would continue executing at the system call vector
- Probably not as the corresponding
- A branch instruction (either
dlEntry.s
(download_entry()
)
This file is considered part of an RTEMS BSP and can be found in ${RTEMS_ROOT}/src/c/src/lib/libbsp/powerpc/virtex5/dlentry
. What's written here is written for the PPC 440 found in Xilinx Virtex 5 parts. The Virtex 4 version is similar.
- In our case, the boot code starts at
startup
- Other names are
start
,download_entry
and__rtems_entry_point
- Other names are
- Boot code vaguely follows the "Initialization Software Requirements" outlined in the PowerPPC 440x5 Embedded Processor Core User's Manual v7.1 from IBM
- Why only "vaguely"?
- Clear MSR
- Disable debug events
- Configure instruction and data cache registers
- Set up decrementer and timer registers
- Clear exception registers ECR and XER
- Invalidate instruction and data caches
- Clear the CPU reservation bit
- Set up CCR0, CCR1, MMUCR, CRF and CTR
- Set up TLB pages
- Set up debug events
- Set up EABI and SYSV environment
- Clear out BSS section
- Load vector offset register
- Set up TOC (i.e.,
r2
) - Set up initial stack (i.e.,
r1
) - Set up argument registers r3, r4 and r5
- Branch to
boot_card()
boot_card()
While the RTEMS structure provides for allowing this function to be supplied by the RTEMS BSP, we use the version that the distribution comes with. It is found in the ${RTEMS_ROOT}/src/c/src/lib/libbsp/shared
directory called bootcard.c
.
In the following, functions prefixed with bsp_
are supplied by the RTEMS BSP.
- Command line is in the first and only argument
- In our system this is always a null pointer
- Disable interrupts
- Store command line
- Call
bsp_start()
- Determine RTEMS work area and heap location and size
- Initialize RTEMS data structures
- Initialize the C library
- This also installs the heap
- Call
bsp_pretasking_hook()
- [Enable RTEMS debugging capabilities]
- RTEMS initialization before loading device drivers
- Call
bsp_predriver_hook()
- Initialize device drivers
- Call
bsp_postdriver_hook()
- Start multitasking
- Before starting the first task call any C++ static constructors.
- Thread with entry point
Init
runs - Not clear how this returns. Perhaps when the last task is deleted?
- Call
bsp_cleanup()
- Return to the start code
- Not clear what's in the
lr
at this point, i.e., where do we return to?
- Not clear what's in the
RTEMS BSP
This constitutes our contributions to RTEMS. The code here sets up the processor and board for generic use. Files related to it can be found in ${RTEMS_ROOT}/src/c/src/lib/libbsp/powerpc/virtex5/...
.
The functions prefixed with app_
are supplied by the RTEMS application, i.e., the RCE project, in our case.
bsp_start()
- Set up default character output function
- Get CPU type and revision cached
- Initialize device driver parameters
- Rate of timer source for
clock.c
bsp_timer_internal_clock
bsp_timer_average_overhead
bsp_timer_least_valid
- Rate of timer source for
- Initialize default raw exception handlers
- Call
app_bsp_start()
- Return to
boot_code()
bsp_pretasking_hook()
- Call
app_bsp_pretasking_hook()
- Return to
boot_code()
- Call
bsp_predriver_hook()
- Call
app_bsp_predriver_hook()
- Return to
boot_code()
- Call
bsp_postdriver_hook()
- Call
rtems_libio_supp_helper()
to open/dev/console
forstdin
,stdout
andstderr
, if it exists - Call
app_bsp_postdriver_hook()
- Return to
boot_code()
- Call
bsp_cleanup()
- Call
app_bsp_cleanup()
- Return to
boot_code()
- Call
RCE BSP
This is the portion of the BSP that is specific to the RCE project. It can be found in release/rce/init/src/Init.cc
.
app_bsp_start()
- This routine should set up the processor and board as needed for the task at hand, i.e., it is not generic.
- Replace the character output function with one that writes to the
syslog
- Return to
bsp_start()
app_bsp_pretasking_hook()
- Initialize
RceDebug
- Initialize
RcePic
- Return to
bsp_pretasking_hook()
- Initialize
app_bsp_predriver_hook()
- Initialize
RceEthernet
- Initialize
RceBsdnet
- Return to
bsp_predriver_hook()
- Initialize
app_bsp_postdriver_hook()
- Return to
bsp_postdriver_hook()
- Return to
app_bsp_cleanup()
- Return to
bsp_cleanup()
- Return to
RceDebug
- Set up an RTEMS extension that creates and manages the
syslog
- Return to
app_bsp_pretasking_hook()
RcePic
- Set up a single PIC Manager
- Set up a vector of PEBs
- Set up a vector of ECDs
- Set up a vector of FLBs
- Set up a vector of PIBs
- Install a BOOK-E Critical exception handler
- Install an External Interrupt handler
- Return to
app_bsp_pretasking_hook()
RceEthernet
- Create a single empty linked list of Ethernet drivers
- Return to
app_bsp_predriver_hook()
RceBsdnet
- Create a single empty linked list of Ethernet handlers
- Return to
app_bsp_predriver_hook()
Init
task
This task is automatically launched by the act of enabling multitasking in boot_card()
- Launch
init_executive()
task - Delete the
Init
task
init_executive()
This function runs in its own RTEMS task that was launched by Init
task. This forms the intent of the loaded executable. Other possibilities exist, but generally, this will be one of the core
executables.
- Announce what's running
- Configure the network from DHCP
- Set up the dynamic linker
- [Start the shell]
- [Start the debugger daemon (
gdb
stub)] - Create a
Task
- Determine what the
Task
should run- Read metadata from flash
- Read the front panel rotary switch
- Dynamically link the code
- Run the
Task