We should normalize the calibration used in offline and configuration building to the best values from L&EO
The input files are listed below, along with the various reports
Base path is $LATMonRoot/ACD/FLIGHT aka
/afs/slac.stanford.edu/g/glast/ground/releases/monitor/ACD/FLIGHT
In each case read
type_of_calib: flavor_or_alias path
FlavorPed: vanilla Ped/081208/r0250381744_ped.xml
FlavorGain: vanilla ElecGain/081208/r0250381744_gain.xml
FlavorHighRange: vanilla HighRange/081208/hr_081208_highRange.xml
FlavorCoherentNoise: vanilla CoherentNoise/081208/r0250381744_coherentNoise.xml
Various reports:
Pedestals
MIP peaks
High range calibration
Coherent Noise Calibration
1 Comment
Anders W. Borgland
The JO to test them if they are in the DB as flavor "test" and in the "DEV" database are:
AcdCalibSvc.FlavorPed = "test";
AcdCalibSvc.FlavorGain = "test";
AcdCalibSvc.FlavorHighRange = "test";
AcdCalibSvc.FlavorCoherentNoise = "test";
and
CalibDataSvc.CalibFlavorList +=
; Brackets are essential
CalibMySQLCnvSvc.QualityList =
;