Motor Configuration
Stage | IOC | PV | Cabling | Status |
---|---|---|---|---|
Newport UTS150PPV6 | ioc-mec-ppl-xps2 | MEC:PPL:MMN:13 | Standard Newport connection from mcn-mec-tch2. | OK |
Micos 6237-C002 Linear Stage, 40mm travel, HV, VSS-42 motor, 16:1 VPGL gear Reference: https://www.pi-usa.us/en/products/precision-motorized-linear-stages | ioc-mec-usrppl-ims | MEC:USR:MMS:25 (formerly XTCS Rotation) | PR60 Patch Panel - DB9 Flange Connection "#4" - Stage Note: Not connecting DB9 from Micos stage containing limit switch information. | PM: We measured the downward and upward motions in response to 5 mm requests. Downward is fine, but upward stops and starts. We recommend cleaning. EG: We don't go to the limits when they are not reliable, we set soft limit 1mm before and after the limits to make sure we don't reach them.I'll be down in the hutch in the afternoon and can have a look at it. |
Micronix VT-50-12316 https://micronixusa.com/product/download/7XReVO/universal-document/xVze6v/VT-50L_Datasheet_v1.5.pdf VT-50L-12316 Motor Type | ioc-mec-usrppl-ims | MEC:USR:MMS:20 (formerly XTCS Filter Wheel) | PR60 Patch Panel - DB15 Flange Connection "2" - Stage | PM: We have verified the cabling for the VT50 out to the cable that comes from the stage. Even when using a VT50 parameter set verified from CXI we saw no motion of the stage.Suggest mechanical inspection. |
Detector Configuration
Detector | DAQ Host | DAQ Configuration | Cabling | Status |
---|---|---|---|---|
Epix10kaQuad0 | daq-mec-pgp02 | -i 0 -P 0x10 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - - Detector | OK |
Epix10kaQuad1 | daq-mec-pgp02 | -i 1 -P 0x20 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - - Detector | OK |
Epix10kaQuad2 | daq-mec-pgp02 | -i 2 -P 0x11 -R 0 -D 0x1760 | Host card 1- (via overhead cable tray - back of PR60 - PR60 patch panel - Flange - Detector | OK |
Epix10kaQuad3 | daq-mec-pgp02 | -i 3 -P 0x21 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - Detector | OK |
epix100a_1_XTCS | daq-mec-cam01 | -i 1 -P 0x20 -G -T -R 0 -D 0x1770 | Host card 0 - R60 E33 RHS patch panel (connection #3) - (via overhead cable tray) back of PR60 - PR60 patch panel - Test Flange - Detector | Working on DAQ and AES driver issues. |
Von Hamos Configuration
Components:
- Remote (vncviewer) access to Windows PC
- Requires Windows machine connected to ICS subnet.
- Windows PC
- Cable from PC to Controller
- Controller
- Cable from Controller to flange
- Cable from flange to Crystals - in vacuum
- Crystals - in vacuum