Sampled Copies of Scalar PVs
We will have both a 10Hz BSA slot and a 1Hz BSA slot for operator tuning.
BSA PV Descriptions
PV Name | PV Description |
---|---|
$(DEV):$(AREA):$(POS):SUMHST0 ... SUMHST63 | Raw power |
$(DEV):$(AREA):$(POS):IMAXHST0 ... IMAXHST63 | Bunch length |
$(DEV):$(AREA):$(POS):TMITHST0 ... TMITHST63 | Transmitted intensity (scaled) |
$(DEV):$(AREA):$(POS):IMAXFLOATHST0 ... IMAXFLOATHST63 | Bunch length (floating point) |
$(DEV):$(AREA):$(POS):SUMFLOATHST0 ... SUMFLOATHST63 | Raw power (floating point) |
$(DEV):$(AREA):$(POS):BLSTATUSHST0 ... BLSTATUSHST63 | BLEN Status: b31: 1 if error happened b30: 1 if in calibration mode b29: 0 if ADC disabled If b31=1, b30=1, or b29=0, all other BSA PVs for the device will be marked "Invalid" |
IMAX Scaling Factor
AppType | Location | IMAX Scaling Factor |
---|---|---|
0 = Pyro | 0 = BC1 | 64 |
0 = Pyro | 1 = BC2 | 8 |
1 = Gap diode | 0 = Injector | 1024 |
1 = Gap diode | 1 = BC1 | 64 |