Blog

Andrews FSJ4-50B

Type of cable or fiber Temp coef (ppm/K) Reference Comments

RG-8A -85 Moore & Kriss 1987

RG-214 -60 Andrew Corp. catalog

RG-223 -40 to -100 Lutes & Diener 1989 Varies with T

Belden 99 13 -21 Moore & Kriss 1987

Andrew FSJ4-50B -2 to +6 Andrew Corp. catalog Varies with T

Andrew LDF2-50 -8 to +6 Andrew Corp. catalog Varies with T

Andrew LDF4-50A +7 to +16 Andrew Corp. catalog Varies with T

Bare SMF-28 optical fiber 8

Dreher 2003 “Loose tube” fiber bundle 8

Navarrini et al. 2003 “Firm buffered” fiber bundle 5

 

These are defaults:

Initial reay 1 setting 2e-9

faulted at 2.5e-10 when vacuum was 4.1e-10

 

GUN vac 4.1e-10

diag vac 6.2e-10

relay 5 sp: 9e-9

Trip occurred at 4e-10 but resets above vacuum level

vacuum interlocks

Sample chamber fast relay sp: 5e-5
This setting has no effect on the interlock. 

Relay 5 5.0e-3

Changed to 3.5e-7 to get a trip. Changed to 5e-5

Chamber pressure 5.3e-7

 

ASTA BLOG

Fire Marshall has approved the use of fire wire on the condition that the modulator capacitors are of the low hazard 'metal clad' variety.