Bugs and Robustness

IssuePersonPriorityStatusNotes

Warning: Unable to save App Designer app object. Save not supported for matlab.apps.AppBase objects. 
Warning: org.epics.ca.Context@42373389 is not serializable 
Warning: org.epics.ca.impl.ChannelImpl@3a027fd6 is not serializable 

SharonLow
Seems to be harmless

Error with HDF5 DAQs

Error using repelem
Replication factors must be nonnegative integer-valued scalars or vectors.

http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2024/24/15.06&pos=2024-06-15T21:36:00

Sharon

Was not able to reproduce this
DAQ crashes and takes down the whole SIOC when total number of shots exceeds 2200 (no streaming, try with streaming on)


Reproduced this with PM03

Has to be more than 5 cameras

Background not being savedSharonHighDONE
Not saving non BSA data and getting F2_EventClass errorSharonHigh
This is caused by a PV in a list being down
Implement HDF5 file saving for imagesSharonHighTesting
Modify DAQ to write image data to "RAM disk"
HighN/A
Calculate how much space on disk is required
High

Install 10G switch and NAS in S10ArjunHighPlanning
Check what happens if new DAQ is started before old one is finished (failed abort)
High

Fix binning and ROI for CMOS cameras
Medium

Can't get magnet values on first DAQ?
Medium

Check that the beam rate is not equal zero if rate set to "BEAM"SpencerMedium

Fix "Use_PV" functionality.SharonMediumDONE
Fix camera triggers if DAQ fails.SharonHighDONE
"Fix cameras" button disabled if DAQ hasnt run yetSharonMediumDONE
"Fix cameras" button should use default values? - yesSharonMediumDONE
Timestamping fails on certain ROI settings?SpencerHighDONE
Upgrade all machines in S20 to 10G connectionSpencerMediumDONE
Camera binning messes up pulse ID findingSpencerMediumDONE

Feature requests

IssuePersonPriorityStatus
Add check/remove bad PVs and notify user in an obvious waySharon

Add nonBSA arrays so we can get UV spectrometer (Claudio request)SharonHighDONE
DAQ Monitor GUISharonHighDONE
Find a way to globally trigger a modifier bit (e.g. "DUMP_2_9").David

Scan function that pauses until you click 'ok'


Generate "camera config" file including trigger info and add a save/restore button. Monitor if this finished ok or not.Sharon

Load/Save Config files. Default config files.Claire

Robustness issues. . .SpencerHighIn progress
DAN featuresSharon

Documentation/commentingSpencerHighIn progress
Fix "Use_PV" functionality.SharonMediumDONE


Documentation

For now, the main references on the DAQ are these attached PDFs from IBIC 2021.


GUI Interface


Main screen → Profile Monitor → LI20 → FACET DAQ (green button)


Wait for a bit after pressing the FACET DAQ button.



DAQ Camera Status GUI

Main screen → Profile Monitor → LI20 → DAQ Camera Status

Indicator lamps light up when a camera is being used by the DAQ, and the "Shots Recorded" field updates as the DAQ runs

  • No labels