Motor Checklist

PurposeBase PVConnectionpmgrpython deviceCabled?Verified/Homed?
Standard Motors
MXI
MXI HexapodMEC:HEX:02Flange T3 to Hexapod 2 controller top of target chamber.N/A
YesYes
MXI linear stageMEC:USR:MMS:21Micronix PPS-110 stage to Flange B7/H<tbd> to PR60 patch panel MEC:USR:MMS:21 connectionCrystal Y


Zyla 500 mm linear stageMEC:PPL:MMN:24

In-air

Direct cabling to XPS3, Card #8

Newport
YesYes

Other Devices Checklist

PurposeBase PVConnectionCabled?Operational?
Permissive Signal
Trigger MEC:USR:AIN:9

User timing and firing unit permissive output (+5V 100 microsec pulse) to R62 EK9000, second  KL3404 (card 11), first channel, PV MEC:USR:AIN:9.

KL3404 specs are "4-channel analog input, voltage, ±10 V, 12 bit, single-ended"

May need pulse extended, e.g. with a function generator, for detection by PLC.

Yes

Detectors Checklist 

DetectorDAQ aliasConnectionCabled?In DAQ?
epix10k-540kquad_0

in-air

Power:

Fiber: 



epix10k-540kquad_1

in-air

Power:

Fiber: 



epix10k-549kquad_2

in-air

Power:

Fiber: 



epix10k-540kquad_3

in-air

Power:

Fiber: 



Andor Zylazyla

in-air

USB/Fiber extender to daq-mec-cam02

YesYes
  • No labels