You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 23 Next »

Individual board testing

Resistance measurements with cable attached

  • Cable was produced in-house, see TIDIDECS-114 - Getting issue details... STATUS
  • There are no serial number on the cables, so for now only using one and assigning it "Cable 01"
  • Measuring between banana connector on the cable and test points on the board

PhotoSENSOR HVHV GNDAGNDP24V0ADGNDP24V0D
Cable 01 - Board 38-C00-02

0.6R0.7R0.4R0.4R0.3R0.3R

Resistance measurements with analog and digital boards mated

Measuring on test points on the analog board.



SENSOR HVDGNDP24V0AP24V0D

Boards
38-C00-01
39-C00-01

AGND0.3R

Voltage measurements with analog and digital boards mated

  • FPGA is not programmed.
  • All power rails are not powered up yet on the digital board, see Issue #3.
  • All power rails on the analog board are disabled by default due to the pull-down resistor R21.


P24V0DP24V0A

Boards
38-C00-01
39-C00-01

Analog board23.96 V24.01 V
Digital board23.96 V24.01 V
Power supply current170 mA0.2 mA
  • No labels