You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 17 Next »

Changing the quad settings

facet home → Profile Monitor → LI20 → SPEC LINE GUI

  • Leave big "Dipole" switch in "Without" setting (dipole energy is not adjusted)
  • Set "Z Object" to the position where the beam should be imaged, e.g., the center of the PB
  • Set "Z Image" to the position of the screen, e.g., z=2015.26 for DTOTR
  • M12, M34: transfer-matrix elements (set both to 0 for re-imaging)
  • Energy: determines where the focus is
  • Press "Calculate and Trim"

Assumptions of this script:

  • Magnet length: 1m
    LEFF_QS0 = 1; % [m]
    LEFF_QS1 = 1; % [m]
    LEFF_QS2 = 1; % [m]
  • Quad positions:
    z_QS0 = 1996.98249; % [m], middle of quad
    z_QS1 = 1999.206615; % [m], middle of quad
    z_QS2 = 2001.431049; % [m], middle of quad
  • Other important positions:
    1993.27370    # [m] FILS
    1992.82000    # [m] PIC_CENT
    2015.62984    # [m] LFOV
    2017.52998    # [m] PRDMP





Changing the dipole settings


Scripts for dealing with the spectrometer

  • No labels