Detector Number | Type | Function | In DAQ? | Notes | Cabled? | Running? | Comments |
---|---|---|---|---|---|---|---|
1 | ePix100a | single photon diagnostics | Yes | in-vac | Yes | Yes | etch 12; vertical holder Q0 fibers/PDU |
2 | ePix100a | single photon diagnostics | Yes | in-vac | Yes | Yes | etch 25; horizontal holder Q1 fibers/PDU |
3 | ePix100a | XRTS | Yes | in-vac | No | Yes | ePix0 Q2 fibers/PDU Recovering from water spill. |
4 | ePix100a | Kalpha User spectrometer | Yes | in-vac | Yes | Q3 fibers/PDU | |
5 | Zyla | MXI | Yes | in-air | Yes | Yes | zyla_xray_east Restart procedure at Zyla and iStar confluence page. Host is daq-mec-cam02. |
6 | XTCAV | Yes | in-vac |
ePix100a SPC vertical → Q0 fiber & PDU S0
ePix100a SPC horizontal → Q1 fiber & PDU S1
ePix100a XRTS → Q2 fiber & PDU S2
ePix100a Kalpha → Q3 fiber & PDU S3
Update on Fiber Mapping: (see 7.11 Opal Camera Configuration for fiber patch panel information)
- Epix 1 - PR60 B1 #3 - R60 A3 #3
- Epix 2 - PR60 B1 #4 - R60 A3 #4
- Epix 3 - PR60 B1 #5 - R60 A3 #5
- Epix 4 - PR60 B1 #6 - R60 A3 #6
- Formerly used by focus_img opal.
- PR60 B1 #2 is the connection with black tape