Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Fibers were tested in fixed locations on the RTM. To ensure that things are working as expected from this table, they should be placed in the same locations on the RTM according to the 2021 mapping.
Fiber / RTM combination | Status |
---|---|
A | OK |
B | OK |
C | OK |
D | OK |
E | OK |
F | OK |
G | OK |
H | OK |
QA of Flange Board ↔ FE0Bs
FEB | FEB SN | Flange Board (HW) | Flange Channel | I At Boot (AnaN, AnaP, Digi) | I Mod ON | I Mod ON + Config | Ctrl Ch (dpm / ch) (1 is top cob) | Fiber (ctrl / Data) | jTag OK | Feb Address | Data Taking | Comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|
L0-1t | 12 | 2 | 2 | 0.242 - 1.212 - 1.250 | 0.292 - 2.317 - 1.392 | 0.292 - 2.833 - 1.322 | 0 / 3 | D / H | Y | 0 | OK | |
L2-3t | 17 | 3 | 0 | 0.256 - 1.248 - 1.239 | 0.317 - 2.319 - 1.314 | 0.313 - 3.112 - 1.313 | 0 / 8 | D / H | Y | 2 | OK | |
L5t | 05 | 0 | 0 | 0.236 - 1.216 - 1.287 | 0.272 - 2.101 - 1.334 | 0.271 - 2.715 - 1.334 | 1 / 5 | A / E | Y | 6 | OK | |
L6t | 16 | 0 | 1 | 0.249 - 1.222 - 1.362 | 0.313 - 2.743 - 1.434 | 0.308 - 3.539 - 1.434 | 1 / 4 | A / E | Y | 8 | OK | |
L4b ( In EPICS is L4t) | 11? | 2 | 1 | 0.248 - 1.241 - 1.248 | 0 / 4 | C / G | Y | 5 | OK | Hybrid 1 and Hybrid 3 give check transaction errors at the power up and configuration. Feb issue? Also noticed two HV pins missing. | ||
L4t ( In EPICS is L4b) | 08? | 1 | 0 | 0.252 1.153 1.374 | 0.307 - 2.8755 - 1.448 | 0.304 - 3.564 - 1.449 | 1 / 8 | B / F | Y | 4 | OK | |
L5b | 20 | 1 | 1 | 0.246 - 1.169 - 1.243 | 0.306 - 2.242 - 1.346 | 0.302 - 3.063 - 1.321 | 1 / 7 | B / F | Y | 7 | OK | |
L6b | 04 | 1 | 2 | 0.248-1.199-1.278 | 0.307 - 2.705 -1.345 | 0.304 - 3.525 - 1.348 | 1 / 6 | B / F | Y | 9 | OK | |
L0-1b | 07 | 2 | 0 | 0.241 - 1.284 - 1.313 | 0.293 - 2.235 - 1.394 | 0.293 - 2.931 - 1.394 | 0 / 5 | C / G | Y | 1 | OK | |
L2-3b | 14 | 3 | 1 | 0.248 - 1.122 - 1.195 | 0.308 - 2.324 - 1.267 | 0.305 - 3.153 - 1.267 | 0 / 7 | D / H | Y | 3 | OK | Timeouts on DPM at first test. After reseating the miniSAS cable (both feb and flange board) data taking was clean. AVDD pin return sense bent |
List of issues we observed during local data taking relative to the Back - End.
NOTICE!!! The dpm numbers in the daq map after 7 are off by one. Example: DataDpm[13] in the DAQ Map is hostname dpm14.