You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 27 Next »

Fibers were tested in fixed locations on the RTM. To ensure that things are working as expected from this table, they should be placed in the same locations on the RTM according to the 2021 mapping.

Fiber / RTM combinationStatus
AOK
BOK
COK
DOK
EOK
FOK
G?
HOK

QA of Flange Board ↔ FE0Bs

FEBFlange Board (HW)Flange ChannelI At Boot (AnaN, AnaP, Digi)I Mod ONI Mod ON + ConfigCtrl Ch
(dpm / ch)
(1 is top cob)
Fiber (ctrl / Data)

jTag OK

Feb AddressData TakingComment
L0-1t220.242 - 1.212 - 1.250

0.292 - 2.317 - 1.392

0.292 - 2.833 - 1.3220 / 3D / HY0OK
L2-3t300.256 - 1.248 - 1.2390.317 - 2.319 - 1.3140.313 - 3.112 - 1.3130 / 8D / HY2OK
L5t000.236 - 1.216 - 1.2870.272 - 2.101 - 1.3340.271 - 2.715 - 1.3341 / 5A / EY6OK
L6t010.249 - 1.222 - 1.3620.313 - 2.743 - 1.4340.308 - 3.539 - 1.4341 / 4A / EY8OK
L4b ( In EPICS is L4t)210.248 - 1.241 - 1.248

0 / 4C / GY5NOHybrid 1 and Hybrid 3 give check transaction errors at the power up and configuration. Feb issue? Also noticed two HV pins missing.
L4t ( In EPICS is L4b)100.252 1.153 1.3740.307 - 2.8755 - 1.4480.304 - 3.564 - 1.4491 / 8B / FY4OK
L5b110.246 - 1.169 - 1.2430.306 - 2.242 - 1.3460.302 - 3.063 - 1.3211 / 7B / FY7OK
L6b120.248-1.199-1.2780.307 - 2.705 -1.3450.304 - 3.525 - 1.3481 / 6B / FY9OK
L0-1b200.241 - 1.284 - 1.3130.293 - 2.235 - 1.3940.293 - 2.931 - 1.3940 / 5C / GY1OK
L2-3b310.248 - 1.122 - 1.1950.308 - 2.324 - 1.2670.305 - 3.153 - 1.2670 / 7D / HY3OKTimeouts on DPM at first test. After reseating the miniSAS cable (both feb and flange board) data taking was clean


Current Issues with Back-end.

List of issues we observed during local data taking relative to the Back - End.
NOTICE!!! The dpm numbers in the daq map after 7 are off by one. Example: DataDpm[13] in the DAQ Map is hostname dpm14.






  • No labels