Fibers were tested in fixed locations on the RTM. To ensure that things are working as expected from this table, they should be placed in the same locations on the RTM according to the 2021 mapping.

FiberStatus
AOK
BOK
COK
DOK
E
F
G
H

QA of Flange Board ↔ FE0Bs

FEBFlange Board (HW)Flange ChannelFlange Board (EPICS)I At Boot (AnaN, AnaP, Digi)I Mod ON and ConfigCtrl Ch
(dpm / ch)
(1 is top cob)
Fiber (ctrl / Data)

jTag OK

Com
L0-1t3210.242 - 1.212 - 1.250
0 / 6D / HYGets clock. No link.
L2-3t3010.256 - 1.248 - 1.239
0 / 8D / HY
L5t0000.236 - 1.216 - 1.287
1 / 5A / E

L6t0100.249 - 1.222 - 1.362
1 / 4A / E

L4b ( In EPICS is L4t)2120.248 - 1.241 - 1.248
0 / 4C / G

L4t ( In EPICS is L4b)1030.252 1.153 1.374
1 / 8B / F

L5b1130.246 - 1.169 - 1.243
1 / 7B / F

L6b123.248-1.199-1.278
1 / 6B / F

L0-1b2020.241 - 1.284 - 1.313
0 / 5C / G

L2-3b3110.248 - 1.122 - 1.195
0 / 7D / H

  • No labels