exp=mfxc00118:run=172 M2.1 - charge injection (CI) run
Request from Chris
O'Grady, Paul Christopher <cpo@slac.stanford.edu> Thu 10/1/2020 11:28 PM Hi Mikhail, For my water-ring data I have to use pixels that are “close together”, so they get roughly the same water-ring signal. That means I have constraints on which pixels I can use and [6,20,97] is too far away. Would it be possible to get your folded AML_L charge-injection plots for these pixels? “bad”: [6,170,103:105] “good”: [6,180,103:105] Thanks... chris
CI data and fits for points
panel 6 170,103
line begin-end: (782,3263)-(1022,3327)
panel 6 170,104
line begin-end: (785,3155)-(1022,3208)
panel 6 170,105
line begin-end: (790,3233)-(1022,3279)
panel 6 180,103
line begin-end: (765,2937)-(1022,3034)
panel 6 180,104
line begin-end: (765,3210)-(1022,3313)
panel 6 180,105
line begin-end: (761,3106)-(1022,3209)