Agenda:
Notes:
Status SVT:
- Hardware – Matt Graham – Thinks everything is working.
- Except one sensor in layer 4 bottom one side (old numbering) which isn't working and probably not recoverable. (Perhaps front end board,)
- Two sensors, layer 6 bottom. that are not turned on, We hope to get those back.
- Layer 0 and 1 seem to be working. Not fully commissioned.
- Some DAQ Mapping issues that are being sorted out right now.
- We see hits when moved to 1.5mm.
- The SVT EVIO - the bank structure changed.
- Omar fixed this.
- Seems to be working except for the DAQ Map.
- Analysis:
- Branch: iss425 (started a while ago) for online monitoring.
- Many other branches are merged into this.
- We need to merge this with master. MAKE A TAG BEFORE THIS MERGE IS DONE.
- We can get clusters on sensors, we can get 3-D hits.
- We don't see any tracks yet.
- We don't have realistic pedestals, so the hits we get don't have realistic times.
- Timing in = middle peak for maximum sample lined up for low current. It looks OK.
- We need to get the pedestals into the database, for all 6 samples.
- No tracks are shown yet.
- Software path forward:
- Make a tag of the current master.
- Start a Run2019 branch that will function as the "master" for all 2019 related changes.
Status Hodoscope:
- The hodoscope readout is done (Rafo)
- It has generic collections, but all info is there.
Status Trigger:
- Trigger Analysis – Rafo
- Loose trigger on only hodoscope: any hit in hodoscope.
- Check if trigger on ECAL works - do we see a cluster.
- Skim on ECAL hits at positron. (seems 99% efficient?)
- Found an issue with the number of hits: it was a signed rather than unsigned int with 4 bits.
- Next Steps:
- Validate the full production trigger.
- The ultimate test will be with the tracking, validating coincidence between calorimeter and hodoscope.
- Needs to still get an improvement with the hodoscope gains for different HV settings.
- Valery:
- We don't need to wait for SVT to be fully operational to verify the Hodoscope trigger. The calorimeter trigger is good.
- The Hodoscope needs to have HV adjusted.
- The Hodoscope rates are very high, The deadline on a single tile becomes >1%.
- The Threshold (TET) for the Hodoscope needs to be adjusted to reduce the rates.
- We still need to do the Hodoscope verification with the data that we took already. We need to test the hodoscope logic.
- Make sure the correlation matrix is correct. We cannot depend on the MC for this.
- We don't need to wait. We need to do this now.
- Rafo:
- Do we need random data?
- No: we can use the calorimeter data only to verify the hodoscope correlations.
- Do you have the code to validate the trigger logic?