20190315 L0M03 previously failed the HV test. It was determined that capacitors on the Hybrid were causing a short, so current was too high on board. 

Capacitors have been replaced at Slac. This test will determine if issue is fixed.

High Voltage Test
V/D:I/D
(V) (uA)
10 0.05
30 0.08
50 0.05
100 0.03
200 2.05
300 0.07
500 0.05

Low Voltage Test
V/D:I/D
Pre-Config
(V) (A)
2.50 0.001
2.50 0.134
1.25 0.000

Post-Config
(V) (A)
Hard Reset works.
Failed to load baseline_config_L0.
CommLink::queueRegister -> Register: Mode, Write, Destination: 0x00000000, Address: 0x01103701, Failed!!!!
CommLink::queueRegister -> Register: Error, Read, Destination: 0x00000000, Address: 0x01103700, Failed!!!!

 

 