Reason for change:

We request to put AlarmsCfg-07-00-12 in production. In this tag we modified the alarm thresholds for the following DQM quantities for channel 2784 (corresponding to Tower 14, layer 4 column 0, face 0) :

- CalXAdcPedPedMeanDeviation_LEX1_TH1

- CalXAdcPedPedMeanDeviation_HEX1_TH1

 A detailed description can be found in the last section of this page.

Test Procedure:

This version of AlarmsCfg has been tested processing locally the monitoring products from two  LPA runs (557369228  and 557380639 ).

Rollback procedure:

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA:

SSC-427 - Getting issue details... STATUS

 

Details:

From release notes for AlarmCfg-07-00-12: