Reason for change

We request to put  AlarmsCfg-07-00-06 in production. In the new tag we are relaxing the upper warning limit on the quantity " AcdPedPedMeanDeviation_PMTB_TH1" for ADC tile 10, as detailed in the last section of this page.

Test Procedure

This version of AlarmsCfg has been tested processing locally the monitoring products from two  LPA runs (490770978 and 490776950).

Rollback procedure

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA

  SSC-413 - Getting issue details... STATUS

Details

From release notes for AlarmCfg-07-00-06:

relaxing  warning limit for AcdPedPedMeanDeviation_PMTB_TH1 (for acd tile 10) in xml/acdpeds_eor_alarms.xml:  

  Upper warning limit changed from 8 to 12.

 

(Datamon tile id 10 refers to tile 220 on the -Y side. )
  • No labels