Purpose

  • short-term goal - support in a single place detectors moving across LCLS experiments.
  • perspective goal - calibration store for LCLS-II

It is assumed that hardware configuration of modern detectors will be associated with configuration index coming from DAQ. This index will be used to extract hardly retrievable calibration data such as geometry, gain factors etc. in case of transition of the detector from one experiment to another.

Requirements

  • Instrument independent - detector can be moved between instruments and hatches.
  • Experiment independent - detector can be moved between experiments.
  • Portability - calibration data for particular detector should be portable as a self consistent file or (part of) calibration directory.
  • Combination of FS & DB files (hdf5 for uniformity).
  • API + GUI for central management.
  • Management can ONLY be done through the API/GUI in order to prevent adding/removing unknown files without history.
  • Time stamp (sec) is THE ONLY value for validity range check.
  • The <detname> is equivalent to <dettype>-<detid> and is THE ONLY choice for the file name. This name is mapped to the custom names in the files with aliases.

Architecture

Calibration directory and files

Default calibration directory in LCLS  FS

instrument and experiment-independent path

  • /reg/g/psdm/detector/calib

in contrast to the current instrument and experiment-dependent path

  • /reg/d/psdm/<INS>/<experiment>/calib

In local space

define calib path

  • <path>/calib/
    assuming further structure of the calibration directory <dettype>/<dettype>-<detid>.h5

or use detector calibration file directly

  • <path>/<dettype>-<detid>.h5

Structure of calibration directory

Everything in lower case:

<path>/calib/
             <dettype>/
             cspad2x2/
             pnccd/
             epix100a/
             cspad/
                       <aliases1>.ali                # file with a map of aliases to detector names
                       ...
                       <aliasesN>.ali                # one of these files can be used to map "sources" to detector names
                       <dettype>-<detid>.h5
                       <dettype>-<detid>.h5

Detector type <dettype>  is used as a folder to organize files under the calib directory. In case of direct access to the hdf5 file the detector type is duplicated in the name of the file. Unique part of the detector name <detid> is used to assign calibration file to the particular detector version. If the detector is changing the new calibration file is created with new <detid>. Information about predecessor and successor (if available) can be saved under the root level of the calibration file. Current sources (ex: 'Camp.0:pnCCD.1' ) should be presented in the dictionary of aliases.

Calibration data hierarchical scheme

Access to calibration data is based on time stamp. Time stamp internally is presented in Unix time sec which can be easily converted forth and back to human readable format YYYY-MM-DDTHH:MM:SS+HH:MM

The scheme of the calibration data, which presumably will be implemented in <dettype>-<detid>.h5

/                                                                   # top-root-level contains info for the unique detector version
 dettype (str)                                                      # detector type name, ex: cspad, pnccd, etc
 detid (str)                                                        # unique detector id, ex: 01234
 tscfile (uint)                                                     # time stamp of creation of this structure
 predecessor (str)                                                  # name of the previous detector if available or None
 successor (str)                                                    # name of the next detector if available or None
 tags (dict)                                                        # dictionary of tags associated with this version of detector
 <ctype>/                                                           # folder for calibration type
          ctype (str)                                               # calibration type name
          tags (dict)                                               # dictionary of tags associated with calibration type
          <tstamp-range>/                                           # folder for time stamp validity range
          <tstamp>[-<tstamp-end>]/                                  # folder for validity range. If <tstamp-end> is not specified - then valid to the end
                                  tsbegin (uint)                    # time stamp for the beginning of the validity range
                                  tsend (uint)                      # time stamp for the end of the validity range
                                  defaultv                          # reference to the default calibration, ex:  <vers-tstamp2>
                                  tags (dict)                       # dictionary of tags associated with validity range
                                  <vers-tstamp1>/                   # folder for version created on tstamp1
                                                 tsvers (uint)      # tstamp1 of this version production 
                                                 calib (ndarray)    # calibration data
                                                 tags (dict)        # dictionary of tags, 
                                                                    #   ex: array size, number of dimensions, shape, data type, experiment, run, comments, author
                                  <vers-tstamp2>/                   # folder for version created on tstamp2
                                                 tsvers (uint)
                                                 calib (ndarray)
                                                 tags (dict)
           <tstamp2>[-<tstamp2-end>]/                               # folder for the next validity range.
 pedestals/                                                         # folder for the next calibration type, pedestals
 rms/                                                               # folder for the next calibration type, rms

Scheme features

  • Detector name consists of a common part <dettype> and unique part <detid>.
  • Alias to the detector name should be kept in separate dictionary outside the scheme.
  • Each detector may have optional predecessor, successor, and other tags in the dictionary.
  • Calibration type folders contain info about calibrations of particular type, ex: pedestals, rms, status, mask, background, etc.
  • Each calibration type contains a set of time stamp ranges defining calibration validity range. If the second time stamp of the range is missing it is considered as infinity (by the end).
  • The time stamp range folder contains tstamp_begin, tstamp_end (int) values, dictionary of tags associated with this folder, reference to the default calibration, and folders with calibration versions, distinguished by there production time stamp.
  • The number of calibration versions for each time stamp range is not limited. Default calibration is defined by the reference default_version.

*

Base class

 


DCBase - base class for this project
====================================
tags        = obj.tags()                 # (dict) dictionary of tags associated with each object
tag         = obj.tag(k)                 # returns tag value for key k


 




 



 

Access methods

DCStore methods
===============
tscfile     = cs.tscfile()               # (int) time stamp of the file creation
dettype     = cs.dettype()               # (str) detector type
detid       = cs.detid()                 # (str) detector id
detname     = cs.detname()               # (str) detector name of self object
predecessor = cs.predecessor()           # (str) detname of predecessor or None
successor   = cs.successor()             # (str) detname of successor or None
ctypes      = cs.ctypes()                # (list) calibration types in the file
cto         = cs.ctypeobj(ctype)         # (DCType ~ h5py.Group) calibration type object


DCType methods
==============
ctype       = cto.ctype()                # (str) of ctype name
tsranges    = cto.ranges()               # (list) of time ranges for ctype
tsro        = cto.rangeobj(tsrange)      # (DCRange ~ h5py.Group) time stamp validity range object


DCRange methods
===============
tsbegin     = tsro.begin()               # (int) time stamp beginning validity range
tsend       = tsro.end()                 # (int) time stamp ending validity range
versions    = tsro.versions()            # (list of uint) versions of calibrations
versodef    = tsro.versdef()             # (DCVersion ~ h5py.Group) reference to the default version in the time-range object
verso       = tsro.versobj(vers)         # (DCVersion ~ h5py.Group) specified version in the time-range object


DCVersion methods
=================
tsvers      = verso.tsprod()             # (int) time stamp of the version production
calibdata   = verso.calib()              # (np.array) calibration array


Management methods

DCBase - base class for this project
====================================
obj.set_tags(d)                    # set (dict) dictionary of tags for object
obj.add_tag(k,v)                   # add (k,v) tag to the dictionary of tags for object
obj.del_tags()                     # delete all tags from the dictionary
obj.del_tag(k)                     # delete tag with key k


DCStore methods
===============
cs.set_tscfile(ts)                 # set (int) time stamp of the file creation  
cs.set_dettype(dettype)            # set (str) detector type
cs.set_detid(detid)                # set (str) detector id
cs.set_detname(detname)            # set (str) detector name of self object
cs.set_predecessor(pred)           # set (str) detname of predecessor or None
cs.set_successor(succ)             # set (str) detname of successor or None
cs.add_ctype(ctype)                # add (str) calibration type to the DCStore object
cs.del_ctype(ctype)                # delete ctype (str) from the DCStore object


DCType methods
==============
cto.add_range(tsr)                 # add (str) of time ranges for ctype
cto.del_range(tsr)                 # delete range from the DCType object


DCRange methods
===============
tsro.set_begin(tsbegin)            # set (int) time stamp beginning validity range
tsro.set_end(tsend)                # set (int) time stamp ending validity range
tsro.add_version(vers)             # set (DCVersion ~ h5py.Group) versions of calibrations
tsro.set_versdef(vers)             # set (DCVersion ~ h5py.Group) versions of calibrations
tsro.del_version(vers)             # delete version


DCVersion methods
=================
verso.set_tsprod(tsprod)           # set (int) time stamp of the version production
verso.add_calib(nda)               # set (np.array) calibration array

*

 

Data and metadata in tags

Below are the lists of fields which potentially can be used to define detector and access calibrations

Detector metadata

Field nameDescriptionMore details, example
dettypedetector typeCSPAD, CSPAD2X2, EPIX100A, etc.
detnamedetector unique name(if any) ex.: Camera1
detaliasalias nameif it is hard to memorize the entire name, ex.: 'cspad1'
detidxdetector indexinteger number which codes the hardware version
detidxaliassymbolic alias of the indexcan be used if it is hard to memorize the index integer number
detcompidx:001list of component indexesjust in case if we are going to retrieve calibration parameters for separate components
detidxprevdetector index for previous versiondetector index for previous version (if available) for the purpose of old calibration search
detidxnextdetector index for next versiondetector index for next version (if available) for the purpose of new calibration search
dettsectime-stamptime stamp associated with beginning of the validity range for new configuration
detcom:001comments for this hardware versionas it says {key:comment}
dettag:001other tagsjust in case if something is forgotten in this table

Calibration parameters' metadata

Field nameDescriptionMore details, example
calibtypecalibration typeex.: geometry, pixel_status, pixel_gain, pedestals, common_mode, etc.
tsectime stampbeginning of the validity range
exporiginal experiment(if available) where calibration constants were obtained
runnumoriginal run number(if available) where calibration constants were obtained
runbeginbegin run number(if available) for validity range
runendend run number(if available) for validity range
sourceoriginal DAQ data sourcedata source from DAQ, ex.: 'CxiDs2.0:Cspad.0'
srcaliasdata source aliasex.: 'cspad'
calibversversion tagin order to access using symbolic name or some alias
calibversaliasversion aliasif it is hard to memorize version tag
com:001comments for this versionas it says {key:comment}
tag:001other tagsjust in case if something is forgotten in this table

In case of numpy array their metadata are stored with an object.
Text file needs in n-d array metadata

n-d array metadata

Field nameDescriptionMore details, example
dtypedata typeint, float, double, etc
ndimsnumber of dimensions (N)as it says
dim:1size of dim.1...
dim:2size of dim.2...
.........
dim:Nsize of dim.N...

API

Parameters

dettype (str) - detector type: cspad, cspad2x2, pnccd, fccd, opal, epix100a, etc.

ctype (str) - calibration type: pedestals, status, rms, mask, gain, bkgd, common_mode, geometry

detid (str) - detector unique id number, ex: 123456

detname (str) - detector unique name, combination of <dettype>-<detid>

detalias (str) - detector alias name assigned to the detname

cpath (str) - path to the calibration directory (ex: cpath='<path>/calib') or direct hdf5 file name (ex: cpath='<path>/<detname>-<detid>.h5'). Default calibration directory CPATH_DEF='/reg/g/psdm/detector/calib'.

version (int) - time stamp of the version creation

 

Initialization

# Import
from PSCalib.DCStore import DCStore       # inport DCStore (Detector Calibration Store) object 

# Initialization
CPATH_DEF = '/reg/g/psdm/detector/calib'  # default calib directory
cpath = '<path>/calib'                    # local calib directory
cpath = '<path>/<dettype>-<detid>.h5'     # direct to file
cpath = env.calibDir()                    # '/reg/d/psdm/<INS>/<experiment>/calib' - accept current directory

detname = 'pnccd-12345678'                # standard name includes detector type, dash, and n-digit id number
detname = 'Camera1'                       # alias

cs = DCStore(cpath, detname)              # creates a DCStore object.
""" get calibration store object
    Input parameters:
    cpath [str] - path to the hdf5 file or calibration directory. 
                  If cpath is a path to hdf5 file - next parameter is ignored.
                  If cpath=None - default path is used.
                  If cpath is specified as a path to directory (or default) then detname can be an alias.  
    detname [str] - name/alias of the detector 
"""

UI - acess methods

p = tstamp parameter to identify constants, which can be retrieved from evt.run() - run number, evt

nda = cs.get(ctype, p) # where ctype stands for pedestals, status, rms, geometry, etc.

# or specific access methods:
nda = cs.pedestals(p)
nda = cs.pixel_status(p)
nda = cs.pixel_rms(p)
nda = cs.pixel_mask(p)
nda = cs.pixel_gain(p)
nda = cs.pixel_bkgd(p)
nda = cs.common_mode(p)

geo = cs.geometry(p)

 

TBD

Open questions

  • What is included in the detector Id version?  FEE version, controller version, etc?
  • when constants are updated (file open to write) they are not available... Lock to resolve.

Data flow

  • who produces and supply constants
  • who is allowed to submit constants
  • who is allowed to access constants
  • ACL inside API or using OS
  • ACL for all or particular detector/type/ etc.