Run 4 Ds1 average gain corrections
- /reg/neh/home/philiph/cxi/myana/gainAnalysis/hantkeGainCorrections_highCut_cleaned_relative.txt (using signal as a function of intensity)
- /reg/neh/home/philiph/cxi/myana/singlePhotonAnalysis/averagedCorrections_cleaned_relative.txt (using single photon peaks at low intensity)
- images at https://confluence.slac.stanford.edu/display/PCDS/CSPad+analysis+meeting%2C+10+August+11
- these should be sensible for any detector
Run 4 DSD metrology (pre-run) , image
- "There are 4 2x1 sensors that do not work. There is also a single 2x1 slot on one of the PCBs that has a bad connection. So the sensor works, but we can't operate it.
- The inner, beam-side 2x2s have tungsten shields, but only one other 2x2 does. Many of these modules were used during Run3 and so have some radiation damage and chipped sensors." - from Chris
Run 4 XPP metrology (pre-run) , image
quad order in file is [0, 3, 1, 2] from looking at IZM modules - more info
- Mikhail's fits are at /reg/d/psdm/xpp/xpp47712/calib/CsPad::CalibV1/XppGon.0:Cspad.0/
- There are 9 types of files:
- center/0-end.data
- center_corr/0-end.data
- marg_gap_shift/0-end.data
- offset/0-end.data
- offset_corr/0-end.data
- quad_rotation/0-end.data
- quad_tilt/0-end.data
- rotation/0-end.data
- tilt/0-end.data
Overview
Content Tools