Property |
Specified Value |
Comment |
---|---|---|
Vacuum Pressure |
10-6 Torr |
|
Maximum Radiation Dose |
1X1014 2 GeV electrons (~3X1013 1MeV NEQ) |
|
Maximum Magnetic Field |
0.55 Tesla |
|
Target |
0.125% X0 Tungsten (approx. 4 microns thickness) |
|
# tracking planes |
5 |
two modules per plane, one above and one below the dead zone |
Sensors per module |
2, in small angle stereo configuration |
|
Stereo angles L1; L2; L3; L4; L5 (mrad) |
(0/100); (0,100); (0,50); (0,50); (0,50) |
stereo sensors dip away from dead zone on electron side. Stereo sensors rotated about centers. |
Nominal dead zone between non-bend sensors w.r.t. photon line (y positions) |
+/- 15 mrad |
between sensitive regions |
z-positions from target (mm) |
100, 200, 300, 500, 700 |
|
x-positions w.r.t. photon line |
0 in all layers |
|
y movement (motorized) |
top and bottom halves move separately in y with +/- 20 mm range |
for nominal positions see dead zone specification above |
pitch movement (motorized) |
+/- 20 mrad |
implied by y adjustability above at both ends in z |
yaw movement (manual) |
+/- 20 mrad |
|
nominal bias voltage |
150V |
|
maximum bias voltage |
500V |
|
Specification |
Allowed Value |
Comment |
---|---|---|
Material |
<1% X0 per measurement pair averaged over tracking volume |
|
Sensor Temperature |
<0C over entire sensor before irradiation |
|
APV25 Temperature |
<30C for all chips |
|
APV25 Temperature Stability |
constant within 3C during physics running |
does not include chip to chip variations, which can be larger |
Flatness |
all sensors planar within 50 microns total |
includes thermal deformation |
Non-bend Alignment of planes |
within 0.5 mrad for all modules on each side of dead zone |
means strips are projective to within 1 strip over entire solid angle |
Stereo Angle Consistency |
within 0.5 mrad of nominal in all layers |
|
Bend-plane alignment stability |
within 10 microns over all sensor surfaces on each side of dead zone during all running |
|
Non-bend alignment stability |
within 25 microns over all sensor surfaces on each side of dead zone during all running |
|
Z alignment stability |
within 50 microns over all sensor surfaces on each side of dead zone during all running |
|