Bugs and Robustness
Issue | Person | Priority | Status |
---|---|---|---|
Modify DAQ to write image data to "RAM disk" | High | ||
Calculate how much space on disk is required | High | ||
Install 10G switch and NAS in S10 | High | ||
Check what happens if new DAQ is started before old one is finished (failed abort) | High | ||
Fix binning and ROI for CMOS cameras | Medium | ||
Can't get magnet values on first DAQ? | Medium | ||
Check that the beam rate is not equal zero if rate set to "BEAM" | Spencer | Medium | |
Fix "Use_PV" functionality. | Sharon | Medium | DONE |
Fix camera triggers if DAQ fails. | Sharon | High | DONE |
"Fix cameras" button disabled if DAQ hasnt run yet | Sharon | Medium | DONE |
"Fix cameras" button should use default values? - yes | Sharon | Medium | DONE |
Timestamping fails on certain ROI settings? | Spencer | High | DONE |
Upgrade all machines in S20 to 10G connection | Spencer | Medium | DONE |
Camera binning messes up pulse ID finding | Spencer | Medium | DONE |
Feature requests
Issue | Person | Priority | Status |
---|---|---|---|
Add nonBSA arrays so we can get UV spectrometer (Claudio request) | Person | High | |
DAQ Monitor GUI | Sharon | High | In Progress |
Find a way to globally trigger a modifier bit (e.g. "DUMP_2_9"). | David | ||
Scan function that pauses until you click 'ok' | |||
Generate "camera config" file including trigger info and add a save/restore button. Monitor if this finished ok or not. | Sharon | ||
Load/Save Config files. Default config files. | Claire | ||
Robustness issues. . . | Spencer | High | In progress |
DAN features | Sharon | ||
Documentation/commenting | Spencer | High | In progress |
Fix "Use_PV" functionality. | Sharon | Medium | DONE |
Documentation
For now, the main references on the DAQ are these attached PDFs from IBIC 2021.
GUI Interface
Main screen → Profile Monitor → LI20 → FACET DAQ (green button)
Wait for a bit after pressing the FACET DAQ button.
DAQ Camera Status GUI
Main screen → Profile Monitor → LI20 → DAQ Camera Status
Indicator lamps light up when a camera is being used by the DAQ, and the "Shots Recorded" field updates as the DAQ runs