Components

  • Mechanics: Front panel, back panel, cooling block and screws.  
  • EpixHR250M carrier, P&CB, and Digital boards


  • 24-channel Fiber optics cable, MTP adapter, on-board transceiver and optical fiber clip


  • On-board transceiver mounting tool and hex keys (3/32'' and 5/64'') 


  • Power cable


  • Thermal pads

Thermal padding

Position two layers of thermal pad on top of the surface of the P&CB that is in contact with the cooling block (large connector side). Two inductors on this side will be visibly coming out from under the thermal pad. These chips have enough height to be in direct contact with the cooling block, and there is no margin for a thermal pad there. Gently remove the thermal pad from the top of the inductors until the inductor becomes visible. 



As for the carrier and the digital board, in some regions it is recommended to use one layer while in others it is recommended to use two layers of thermal pads. See image below




Connecting transceiver