These are data files that are publicly available using DataSource('exp=EXPNAME:run=NNN'), where NNN can be found in the first column below, and EXPNAME is xpptut15 for the first table below, and cxitut13 for the second table below.

 xpptut15 starting run numberData origin (expt, run(s))  Comments
AMO

 290amoc0113  217,219 see run 280 notes
280amoi0216  32,34,

(from Timur Osipov) if I remember it correctly there were two acqires boards (1 and 2?) one broken into 4 channels and the second one just one (or two) channel. The one with 4 channels would be the coordinates for the square delay-line (0 - x1, 1 - x2, 2 - y1, 3 - y2), the other one, with the fewer channels, should be the MCP - TOF channel for the delay line.

As for the phosphor screen detector the files from the commissioning of the LAMP (amoc0113) should work - runs 217, 219, 220 each is a couple minutes long with opal images of the phosphor detector.

390amod3814, 85(from Timur Osipov)  HEX anode data: amod3814, runs 85, 88, 90, etc. any decently sized files. Channel assignments including ACQIRIS: PINOUT
340

amo06516

10,15,19

pnccd flat-field data (1.74 keV photons from Si k-alpha)
350

amo01616

125

(From Alex Reid) Andor camera: Portable X-ray Spectrometer RIXS measurement on CoO, grating in 2nd order, beam energy 780 eV. Andor only read out every 7000 events or so.
360

amo01616

20

(From Alex Reid) Emission spectra on Cu measured using the SXR portable spectrometer with Andor detector in full vertical binning mode (120 Hz readout rate)
310amol9416  272long gain 6 dark for front pnCCD
620amox23616 104,131,137xtcav dark (104), lasing-off (131), lasing-on runs (137)



CXI

101,102,124cxii0314xtcav: 101: lasing off, 102: dark, 124: lasing on
270cxi06216  22crystallography run
380

cxilp9915

162

(From TJ Lane) dark run contains two CSPAD cameras (front/back aka DS1/DSD) in a single datastream at CXI
370

cxilp7315

21

(From Sebatien Boutet) Two laser flash data for jet speed measurement using Opal1K camera at 120Hz. Also contains 120Hz cspad.
580cxilw5019 248 thru 250(Requested by Mark Hunter) Lysozyme data on jungfrau4M detector
610cxilu9218 12

SF6 geometry calibration data on jungfrau4M detector




MEC

460

mec70013

454

two princetons  PI-MTE with weak XRTS signal. Also has Opals and cspads.
470

meco1416

250, 256

PCI experiment, images here from the PI-PIXIS camera.

run 470: 10 dark images, run 471: images with X-ray beam and fringes

480

mecls3115

157 thru 168

data of optical beam (long pulse) on OPAL camera.

run 489 is good: it has some images with different camera positions and ~20 events.

500

mecdaq115

71, 72

data of standard configuration, with 3 quads and 2 140k.

run 500: calibration data on LaB6, at 7.2keV. run 501: calibration data on CeO2 at 7.2keV

510

mecx24215

72, 121

run 510: images on our Peter Optique with the Neo.

run 511: data on both the IPM3, GMD and PIP diode (MEC-TCTR-DI-01:FEX) behind the chamber




MFX

430

mfx11116 664, 677

High and lower-flux Jungfrau 1Megapixel attenuation scans
410mfx11116 691,694Jungfrau 0.5M data
550mfxx45919 9-18Scattering from water droplets on ePix10k
570mfxx45919 80-85Protein crystal scattering from droplets on ePix10k
590meclx9920 634MecTargetChamber.0:Epix10kaQuad.0/1/2/3



SXR

520sxrx21715 191Saturated digitizer data
450sxrx20915 40,64"front" pnCCD runs in gain 5 from Phil Hart. run 40: dark. run 64: Fe55 flat-field data
440sxrx21715, 193both acqiris and new high speed digitizer waveforms excited by x-rays
420sxrx24615Timetool data (spatial)
400sxri0215, 155

SXR time resolved XAS scan using FCCD detector in full vertical binning mode with MCP I0. 

330sxr82112 197Practice encoder data for determining pump-probe time (but no extra time-tool information)



XCS

260xcs01116  81,82,83,120epix100: 81(dark), 82,83(vonHamos), 120(speckle)



XPP

54,59XPP test DAQ Runs59 contains slow epics data
140xppi0813 75-85,8787 is dark, also has timetool epics values
160xppc0114 287
170xppc0115 270
180xppf2115189,190,192, detector is cspad 140k, data are "samr" scans.
190xpp72213  324,300detector is cspad 140k, data are most likely delay scans.
200xppd0115  375,366366 is dark, 375 is delay scan, detector is a cspad 140k.
210xppi3815  224,225ccmE_vernier scan, detector is a diode on the end station IPM (diodeU), channel3. A 140k is used for the spectrometer.
220xppi3815  100-104delay scans.
230xpph4915  17
240xppc0115  328,335328 is rayonix with 2x2 binning, 335 has 10x10
250xpp02016 225,272,300New delay scan implementation 
320xppl4416 283,284XPP cspad data and shows powder rings. LaB6 is the sample.
600xppx53620 74
630xppx49520 267,602Split-pulse XPCS data. (Sparse) photons on jungfrau1M & epix100 detectors.



MISC

300diamcc14  920,921,922xtcav: dark,lasing-off,lasing-on xtcav. s00 renamed to s80
530detdaq17 256 (modified! to fix incorrect detid's)Jungfrau 4M. NOTE: actual data was copied from files with "fixed up" detid's in /reg/d/psdm/det/detdaq17/scratch/philiph/jungfrau/ASC/e968-r1256-s00-c00.xtc /reg/d/psdm/det/detdaq17/scratch/philiph/jungfrau/ASC/e968-r1256-s01-c00.xtc
540xcsx35617 421Epix10ka2M dark run

See https://github.com/chrisvam/psana_cpo/blob/master/xpptut15_copy.py for a script to copy runs into /reg/d/psdm/xpp/xpptut15/, which automatically updates the run number in the filename and for the xtc begin-run transition.  It also attempts to copy over relevant calibration constants.

cxitut13 run numberData originComments
10cxi06216  22lysozyme crystallography tutorial data
11cxi06216 17dark data for the above
20cxi00516 6

8keV flat-field data on DsaCsPad

30cxi12016 24

Diode wire scan with Imp detector