You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

Runs Digest

The following is a digest of the T9 runs. Get the full list or the selected run from the pipeline or elogbook. (WORK IN PROGRESS)

 Electron runs

 Runs

 Date

particle

energy

CU configuration

CU position

AD

notes

 1201

 11/8

e- 

 2.5

 BT1

 

 

 av rate 34 HZ, CU instant rate 500 hz. S0 counts 21k per spîll

 1202

 

 e-

 2.5

 BT1

 

 

 3 phasing errors for 30k events. run stopped due to beam off

1205


e-

1.




S0:14 k count per spill
HW trg: 700 count per spill
DAQ trg: 300 count per spill
beam divergence: 6.3mrad on XZ, 5mrad on YZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tagged photon runs

 Runs

 Date

particle

energy

IMagnet 

CU configuration

CU position

AD

notes

1176 

 

tagged g

3GeV

 600

BT1

0 degrees, center of tower 2

yes 

events in twr3?

 1177-1180

 

tagged g

e beam at 2.5GeV

 600

BT1

0 degrees, center of tower 2

yes

magnet ON, 25K evts per run 

 1206

 

 tagged gamma

e-  1GeV

 240

 

 

 

 S0:14k count per spill
HW trg: 100 count per spill
DAQ trg: 100 count per spill
Lot of 0 cluster in chamber 2 and 3, we need to tune the bending magnet and/or improve the veto to select a small spot.

 1207

 11/8

 

 

 

 

 

 

 idem with S1 in the trigger
this run is to see if the zero that we see is a trigger or magner problem:

  • it seem that it's a trigger issue: now the fraction of zero seems similar to what we saw in the other physics runs.
    S0: 14 k count
    HW & DAQ trg :20 counts

 1208

11/8 11h34

 

 e-
1 GeV

 240

 

 


   New trigger S3 in veto 
count per spill:
S0: 12k
HW: 50
DAQ: 60

 1209

 11/8
13h29 

 

 e-
1GeV

 

 

 

 

 Slits position changed from 51.5 to 52: S0 rate passed form 14 kCount to 20 kCount per spill. good tagged run with 1GeV beam.
trigger counts per spill (2 spill per cycle):
S0: 20k
HW: 80
DAQ: 70
  around 30k : SYNCHRONIZATION LOST !
stopping the run, first 30000 events should well sycnhronized...
for the event for which the synchronization was lost the DeltaEventTime was 128s that is corresponding to the turnover of the 2nd GASU counter. ||

1210 

 11/8

 

 

 

 

 

 

 Synchronized Tagged gamma with 1GeV electron beam, going for 70k to get all the statistic
+ beam intensity is very low : DAQ rate ~ 15events/spill and S0 ~ 2700events/spill
+ after 12k : we have 3 spills taking ~200 events per super cycle

1210 

 11/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full-brem Photon runs

 Runs

 Date

particle

energy

 I(Magnet)

CU configuration

CU position

AD

notes

1183-1190

 8/8
9/8 

e+g

2.5

 600

BT1

0 degrees, center of tower 2

yes 

overall 2M evts  - (false report of 300 A for 1185 in elogBook)


 



 





 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tagger calibration runs

 Runs

Date 

particle

energy (GeV)

CU configuration

CU position

AD

notes

 1148-1164; 1166-1169

 8/8

e beam

various

BT1

0 degrees, various positions to align with tagger

yes

many different configurations, for expert only

 1170

 

e beam

1.5

BT1

0 degrees, center of tower 2

 yes

 dump in place, slits at 51.5

 1171

 

e beam

1.25 

BT1

0 degrees, center of tower 2

 yes

magnet current 600A, direct tagger calibration

 1172

 

e beam

1.125

BT1

0 degrees, center of tower 2

 yes

magnet current 600A, direct tagger calibration-NOT Synchronised

 1173

 

e beam

 1.375

BT1

0 degrees, center of tower 2

 yes

magnet current 600A, direct tagger calibration, slits reduce to 51

 1174

 

e beam

1.125 

 BT1

0 degrees, center of tower 2

yes

magnet current 600A, direct tagger calibration

 

 

 

 

 

 

 

 

 CAL calibration runs

 Runs

particle

energy

CU configuration

CU position

AD

notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAL pedestal runs

 Runs

Date 

particle

energy

CU configuration

CU position

AD

notes

 1191

 9/8 8h51

-

-

 BT22 (S3 only)

-

-

monitor pedestal shift

 1165

 8/8

 

 

 BT22(S3 only)

 

 

 pedestal

 1198

 10/8

 

 

 BT22

 

 

 pedestal T ~22.3C

 1201

 11/8

 

 

 BT22

 

 

 Pedestal T~ ?

ACD Calibration runs

Runs

Date 

particle

energy

CU configuration

CU position

AD

notes

 1192, 1193

 9/8

 cosmic

 

 

 

 

 

 1194-1197

10/8 

 cosmic

 

 BT3

 

 

 

 

Sil Calibration runs

Runs

Date 

particle

energy

CU configuration

CU position

AD

notes

 4318

 11/8

 

 

 

 

 

 

 

Not to be used 

Runs

Date 

particle

energy

 IMagnet

CU configuration

CU position

AD

notes 

 1200

 11/8

 e-

 2.5

 0

 

 

 

 ? Control Room ajustingSpill structure during run

 1203

  11/8

 e-

0.5 

  0

 

 

 

 S0 = 13k/spill, wrong focus setting

 1204

 11/8

 e-

 0.5

 0

 

 

 

9 mrad on XY 12 mrad on XZ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • No labels