Detector | DAQ alias | Connection | Cabled? | In DAQ? |
---|
epix10k-540k | quad_0 Fiber: - B2/#1,#2
- PR60 E15 Middle #1
- R62 E33 Right #2
- MTP to daq-mec-pgp02
- rear
- upper right side
- left most fiber port
| B3/- vac cable -> Flange B3, Q0 feedthru -> air cable "epix10k quad 0" -> MPOD quad outlet 0
- Note: vac cable labeled "PDU Cable Epix10k Q0" on quad side but "epix10k quad2" on flange side.
- Fiber: using "epix10k quad 0" vacuum and air fibers. Flange B2, feedthru pair 0 -> PR60 patch panel quad port 0
| Yes | Yes |
epix10k-540k | quad_2 | - Power: TBD -> Flange B3, Q2 feedthru -> air cable "epix10k quad 2" -> MPOD quad outlet 2
- Fiber: using "epix10k quad 2" vacuum and air fibers. Flange B2, feedthru pair 2 -> PR60 patch panel quad port 2
- Note on vacuum power cables:
- Using cable "PDU Cable epix10k Q1": Minor alarm on DVDD when ON, HV error when failed to configure in the DAQ.
- There is a second cable from Phil "epix10k quad 0" that I have not tested. It is on the optical table.
| Fiber only, no power. | No |
epix10k-540k | quad_3 | - Power: Quad 3 vac cable -> Flange B3, Q3 feedthru -> air cable "C01 April 2024" -> MPOD quad outlet 3
- Fiber: using "epix10k quad 3" vacuum and air fibers. Flange B2, feedthru pair 3 -> PR60 patch panel quad port 3
| Yes | Yes | epix10k-540k | quad_2 | Details worked out with Detectors Group. Fiber:
B2/#7,#8PR60 E15 Middle #4 R62 E33 Right #2MTP to daq-mec-pgp02rearupper right sideleft most fiber port
Power: B3/Quad 3
| epix10k-540k | quad_3 | Fiber: - B2/#7,#8
- PR60 E15 Middle #4
- R62 E33 Right #2
- MTP to daq-mec-pgp02
- rear
- upper right side
- left most fiber port
Power: B3/Quad 3 |
ePix100 | SW Epix100a "epix100a_f" | - Power: Flange B3, South feedthru -> power cable E1 -> MPOD outlet 1
- Fiber: using "epix100a epix 1" vacuum and air fibers. Flange D2 (left) -> PR60 patch panel epix port 1 → MTP to daq-mec-cam01
- MECHome: "Epix 1"
- DAQ: "epix100a_1_bxrts"
| Yes | Yes |
ePix100 | NE Epix100a "epix100a_b" | - Power: Flange B3, North feedthru -> power cable E0 -> MPOD outlet 2
- Fiber: using "epix100a epix 0" vacuum and air fibers. Flange D2 (upper) -> PR60 patch panel epix port 2 → MTP to daq-mec-cam01
- MECHome: "Epix 2"
- DAQ: "epix100a_2_fxrts"
| Yes | Yes |
Andor Zyla | zyla | in-air USB/Fiber extender to daq-mec-cam02 | Yes | Yes |
VISAR 1 | visar_1 | Network connection with Windows PC ioc-mec-visar1 | Yes | Yes Not tested right now since under regular use |
VISAR_2 | visar_2 | Network connection with WIndows PC ioc-mec-visar2 | Yes | Yes Not tested right now since under regular use |
Diode/Wave8 | PVs are: - MEC:XT2-1:BMMON:*
- MEC:XT2-2:BMMON:*
| TBD | Yes | Yes: see Jira |
---|
server | SLAC National Accelerator Laboratory |
---|
serverId | 1b8dc293-975d-3f2d-b988-18fd9aec1546 |
---|
key | ECS-5105 |
---|
|
.
|
Timing diode/QADC134 | PVs are: | B3 ioc-mec-qadc. Timing fiber connected. Diode signal into A1 with SMA/Male - SSMC/Female Coaxial Jumper Cable and VLM-83-2W-S+ limiter. | Yes
| |
XRT spectrometer | hxsss | N/A | N/A |
|