Some technical details from a discussion on March 23, 2023

currently start sequences on 1Hz boundary.  this slows down the daq scan steps, so a second mode is being considered:

(1) current seq mode (only program time-in-seconds or numL1Accepts)
    have to coordinate the start of an accelerator burst with the daq sequence
    - are there two sequences?  one for accelerator and one for daq?
      not clear how much control the accelerator will want (e.g. burst
      all the time for stability, but silke says can damage samples)
    - each step we start one sequence:
      o may also include control of accelerator, but if not
      o have to coordinate the start of the daq seq with accelerator seq
        o acc seq synced to 1Hz marker (everything repeats at 1Hz on
      accelerator side)
    o trickier to sync to rates faster than 1Hz
(2) future-firmware seq mode
    - make the daq enable/disable on a user-defined event code
      o would be faster on the enable since don't have to wait for 1Hz
        marker.  still have to understand the periodicity of the accelerator
    so the user-defined event codes get sent down at the right time
    but it does mean we don't need the slow 1Hz marker.  some things like
    laser electronic delay scanning may be faster than 1Hz so could benefit
    from not using the 1Hz marker.caveat: currently start sequences on 1Hz boundary

andor integrates over 10 shots
6 andor images in a step

...