Attention: the alignment target can crash with multiple items. Please contact E-320 if you don't know the procedures.

Motor positions after rejigging MO (height change): http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/35/31.08&pos=2022-08-31T17:05:58 (outdated)

New motor positions since Nov 16, 2022! (table needs to be updated)

DescXPS ControllerMotor nameChannelPositionDesc. positionLast update
USHMXPS:LI20:MC03PB10 M2 Removal StageMC03, M1

OAPs in: 42.

5 mm away from the electron beam / axicon position

laser vector alignment: 0.5

(cross-check with 305 value above)

E-320 position: mirror on the right side of the e-beam, steering laser onto 1st OAPAugust 31, 2022

Alignment Target Vertical

UP/DOWN

XPS:LI20:MC10PB11 SFQED Target VerticalMC10, M10/99/
48
50.
7

Home position, needed when inserting or retracting OAP assembly. Do not drive to home (0) when MO tower is in IN position.

/Clear position with and without OAP assembly. Moving assembly requires moving out of clear position.

2

highest position / lowest position / YAG in position

ATTENTION: collisions possible, follow exact procedure, check target position before moving OAPs / MO tower

December 14, 2022
/In electron and laser beam path
MO Tower Mover IN/OUTXPS:LI20:MC10PB12 SFQED Tower MoverMC10, M2

-

94.2

95/0

IN position to look at focal spot.


Clear (retracted), also home position, needs to be done before retracting SFQED assembly

December 14, 2022
OAP Assembly IN/OUTXPS:LI20:MC10PB16 SFQED Assembly RemovalMC10, M3
117
116/0

IN position to focus main beam.

Clear (retracted), also home positions, needs MO Tower to move out first, also needs Alignment target to move upwards first

December 14, 2022
Elliptical mirror/M3 IN/OUTXPS:LI20:MC10PB17 Elliptical mirror moverMC10, M4Positive limit switch/negative limit switch + 7

Out position. Configuration is 'SetCurrentPositionAsHome',so need to drive all the way to positive limit switch to ensure driven out.

In position. Drive all the way to negative end for IN position.


PB18 Focus Imaging VerticalXPS:LI20:MC10PB18 Focus Imaging VerticalMC10, M56.23Home at current position (0). Motor should not be touched or moved, should be clear in any case.
Foils vertical moverXPS:LI20:MC05
MC05, M180 (foils in for beam vector alignment)needed only for beam-vector alignment (M1/M2)December 14, 2022
Foils horizontal moverXPS:LI20:MC05
MC05, M2-95 (foils in for beam vector alignment)needed only for beam-vector alignment (M1/M2)December 14, 2022

December 14, 2022: http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/50/14.12&pos=2022-12-14T23:59:00