NOTE: If we couple all readout-group deadtime then we don't learn how many high-rate shots we drop with integrating detectors, but Matt suggests putting in a counter in the timing stream that counts the number of deadtimed-events and attaches that counter to the data stream when it can readout: the counter will often be zero, but will be non-zero in the case where we have deadtime.  Matt points out that MPS can effectively change the rate of beam, so we can't depend on a fixed-rate beam.

...