(ps-4.5.11) claus@drp-srcf-cmp005:srcf$ pykcu -d /dev/datadev_1 -P DAQ:SRCF & Start: Started zmqServer on ports 9103-9105 ClkRates: (0.0, 0.0) RTT: ((0, 0), (0, 0), (0, 0), (0, 0)) 2022-03-16T18:24:31.976 Using dynamically assigned TCP port 56828. Then run pvget to see optical powers: (ps-4.5.11) claus@drp-srcf-cmp005:srcf$ pvget DAQ:SRCF:DRP_SRCF_CMP005:MON DAQ:SRCF:DRP_SRCF_CMP005:MON 2022-03-16 18:24:31.983 RxPwr TxBiasI FullTT nFullTT 1.017 37.312 0 0 0.424 37.376 0 0 0.3964 38.272 0 0 0.3208 36.992 0 0 |
For a timing system node we would have only expected fiber power on the first, but Riccardo saw power on the first and fourth. Matt writes about this: "I agree with your observation and the conversion formula. In general, I'm finding the RxPwr number on lane 0 is inconsistent or suspicious.". (conversion formula is what we use for xpm: dBm=10*log(10)(val/1mW))
this is the correct firmware to program into the kcu:
Code Block drp-neh-cmp001:~$ ls -rtl ~weaver/mcs/*TDet*2020* -rw-r--r-- 1 weaver ec 31345008 Jun 12 2020 /cds/home/w/weaver/mcs/DrpTDet-20200612_primary.mcs -rw-r--r-- 1 weaver ec 31345008 Jun 12 2020 /cds/home/w/weaver/mcs/DrpTDet-20200612_secondary.mcs drp-neh-cmp001:~$
...