The -s
specifies the serial number used (00000000 is the default one for Optoboard V2.1), -G
is the link number of FELIX and -d
the FELIX device. If -s
is set to 00000000 and -v 1.3
, optoboard_felix sends the parameters in the config ~/optoboard_felix/configs/optoboard_lpgbtv1_gbcr2_vtrxv1_3_default.json
to the lpGBTs, GBCR and VTRx+. Check the FELIX documentation or the optoboard_felix readme for more information on this.
If you do flx-info link
you should see that respective link aligned. If you do flx-info podpower
you should see something like this (if single Optoboard outside test-Optopanel is connected similarly:
Code Block |
---|
Optical power (Receive=RX or Transmit=TX) of channel in uW:
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
|=========|=========|=========|=========|=========|=========|=========|=========|=========|=========|=========|=========|
1st TX | 983.30 | 986.10 | 892.10 | 970.00 | 937.50 | 1009.70 | 916.20 | 970.30 | 920.00 | 960.80 | 924.40 | 958.50 |
1st RX | 946.80 | 790.20 | 870.50 | 761.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
After fibre fanout installation:
After the fibre fanout is installed, configuring the Optoboards will look similar to this:
...
slot: | OB1 | OB2 | OB3 | OB4 | OB5 | OB6 | OB7 | OB8 |
---|---|---|---|---|---|---|---|---|
serial: | 2400006 | - | 2400003 | - | 2400007 | - | 2400011 | - |
powering from bPOL: | A | A | B | B | C | C | D | D |
current* [mA] | 182 | 165 | 168 | 174 | ||||
FELIX link: |
*after power-up and inside the test-Optopanel with 9.0 V supplied. If powered outside the test-Optopanel directly on the connector with 2.5 V expect a current ~415 mA.
Connectors:
Check the above interfaces document for more detailled description.
...