- check Pixel-Clock in lower right (should be green text)
- should auto-detect camera on software startup: board->attached camera→camerainformation
- image format->test pattern→ramp
- i/o controls→trigger mode was on (means waiting for trigger)
- advanced control→line sync source→internal line trigger
- linetriggermethodsetting use method1
- use CC1 trigger pulse pulse#1
- image buffer and roi → camera sensor and geometry setting → 8X-1Y
- image height (in Lines) changed to 1000
- frame grabber leds flashing green when things working
- can move camera back to factory settings
- restarting cam expert is faster than auto-detecting camera
- can select between stored different camera configurations (stored inside camera)
- all fields green in lower right of cam expert (pixel clocks (3) and line valid). Pocl's red
- "board" section is the frame grabber. everything else is camera related.
- "Device:" Xtiunm-CL_MX4_1 size options: are the server options. we only want full mono. "camera link_1" is the serial port (the latter is almost legacy)
- histogram option in upper right. open it first (bug) then click "grab"
- camera information→power configuration set to factory setting.
- be careful with internal/external triggering
- frame-rate is for many lines
- what data gets is "focus dependent": depends on what is selected in menu in lower left, either frame grabber OR camera config is saved
- we want file->preferences→NOframegrabberconfigfileonly (will also stores like the external/trigger setting). and we need we need to set "focus"
- two types of files: camera configuration file, and frame-grabber configuration. both files have same extension. (remember focus-dependent saving)
- path to ccs files: c:\programfiles\teledyneDalsa\sapera\camfiles\user
- File→Open Chrisb_test.ccf in above directory, I think