Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

3a) Trigger based on a Destination receiving Beam1MHz + Include Dest

Rate Mode = Fixed

Fixed Rate = 1MHz

Destination Mode =  Include

Destination Mask = Dest Bit

Ch Enabled → Only when you are done configuring, to avoid high undesired triggers on your device!

This will trigger your device in either Fixed rate or AC Rate beam, anytime there is beam.

3b)  Trigger based on Destination and Particular Rate (Device Rate Limited)

Fixed Rate

AC Rate

3c) Trigger based on a particular rate but no destination requirement

AC and/or Fixed Rate at a Lower rate than beam rate with Destination Requirement

Fixed Rate Case:

Rate Mode = Fixed

Fixed Rate = 10Hz

Destination Mode =  Include

Destination Mask = Dest Bit

Ch Enabled → Only when you are done configuring, to avoid high undesired triggers on your device!


AC Rate Case:

Rate Mode = AC

AC Rate = 10Hz

Destination Mode =  Include

Destination Mask = Dest Bit

Ch Enabled → Only when you are done configuring, to avoid high undesired triggers on your device!Dest Mode = Don't Care


3c)Trigger based on AC and/or Fixed Rate at Lower a Lower rate than beam rate withOUT Destination Requirement

Fixed Rate Case:

Rate Mode = Fixed

Fixed Rate = 10Hz

Destination Mode =  Don't care

Ch Enabled → Only when you are done configuring, to avoid high undesired triggers on your device!


AC Rate Case:

Rate Mode = AC

AC Rate = 10Hz

Destination Mode =  Don't care

Ch Enabled → Only when you are done configuring, to avoid high undesired triggers on your device!


3d)

Trigger on special bits like the Calibration Bit for BPMS → Control Sequence Setup

...