Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

How to start gas jet operation


DO NOT FOLLOW THIS PAGE! - Go here instead: How to use the gas jets!


  1. Check first of all that the Experiment Protection System is not faulted. Go to facethome and LI20-Experimenter. Click the E-300 Oven button in the lower left corner. This takes you to a screen where you can see if the gas source is enabled or disabled. If it is disabled, then hit the EPS Reset button. If this does not fix it, it needs some expert attention which probably means talking to Christine Clarke or Doug Storey.
  2. Go to facethome and LI20-Experimenter. From there, select the Beckhoff Digital I/O button (the screen shows items grouped by racks- these electronics are located in rack FKG20-26). When you launch the Beckhoff system, you see the image below. The gasline valve controls are a 24 V out module. They are the module furthest to the right. See the red box. When you click this, you see options to toggle the fill and drain valves.

...