c) From process out (chiller) to filter | ||||
Coolant connector (3/8" CPC) on unit #2 (PROCESS OUT) | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff: link | 3/8" ID 1/2" OD tube (E-3603 Tygon PVC Tubing for Chemicals ) link45 cm (?) | 3/8" MNPT x 3/8" Hose Barb Polypropylene ElbowLink | 3/8 NPT female interface of filter housing link |
---|---|---|---|---|
|
...
From filter(out) to application (cold plate) | |||||||||
3/8 NPT female interface filter housinglinkLink | 3/8" NPT HFC 12 Series Polypropylene Coupling Body - ShutofflinkLink | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff:linkLink | 3/8" ID 1/2"OD tube( E-3603 Tygon PVC Tubing for Chemicals ) link 15 cm | Brass Barbed Hose Fitting for Air and WaterWater(Straight Reducer for 3/8" x 1/4" HoseID) linkID )Link | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals)Link30 cm | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Body Body ) SS-QC6-B-600 (3/8") | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Stem with Valve Valve ) SS-QC6-D-600 (3/8") | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 140 cm | cold plate (can fit 1/4 " ID) |
---|---|---|---|---|---|---|---|---|---|
...
From application (cold plate) to chiller (process in) | |||||||||
cold plate (can fit 1/4 " ID) | 1/4" ID and 3/8" OD ( E-3603 Tygon PVC Tubing for Chemicals) 140 cm | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Body ) SS-QC6-B-600 (3/8") | Swagelok Instrumentation quick connect ( Stainless Steel Instrumentation Quick Connect Stem with Valve Valve ) SS-QC6-D-600 (3/8") | 1/4" ID and 3/8" OD( E-3603 Tygon PVC Tubing for Chemicals)Link30 cm | Brass Barbed Hose Fitting for Air and Water(Straight Reducer for 3/8" x 1/4" HoseIDID )) linkLink | 3/8" ID 1/2"OD tube(E-3603 Tygon PVC Tubing for Chemicals)linkLink15 cm | 3/8" Hose Barb HFC 12 Series Polypropylene Elbow Coupling Insert - Shutoff:linkLink | 3/4" NPT HFC 12 Series Polypropylene Coupling Body - ShutofflinkLink | Coolant connector (3/8" CPC) on unit #2 (PROCESS in) |
---|---|---|---|---|---|---|---|---|---|
|
...
Left pump port with 3/8" barb | High-Pressure Firm Polyurethane Rubber TubingID:OD=3/8":5/8" Link ~1.5 m | 316 Stainless Steel Push-on Hose Fitting for Air and Water3/8" Hose ID, 1/4 NPT Male End Link | On/off valve High-Pressure Compact 316 Stainless Steel On/Off Valvewith Lever Handle, 1/4 NPT Female x 1/4 NPT MaleLink | 1/4" Tee316 Stainless Steel Threaded Pipe FittingLow-Pressure, Tee Connector, 1/4 NPT Female | Plastic Barbed Tube Fitting for Air and WaterSwivel Adapter, for 1/16" Tube ID (1.6 mm)x 1/4 NPT Male | cern tube OD/ID=3mm/1.8mm (~30cm) |
---|---|---|---|---|---|---|
...
The dry air filters were saved by Matt from BaBar, residing inside the curtained area of B84 EPP lab. House compressed air are filtered to let out through the flow meter with a max flow of 20 ft3/min. A 80ft long hard polypropylene tubing with 1/4" OD (McMaster-Carr #9349T2) takes the drive air down to the ATLAS benches. The dry air supply tube terminates at a diverting valve (no shutoff) (McMaster #45165K42) on the bench to allow the switching of the dry air between a test port and the through path to module cooling unit. The through path continues with the same type of tube to transition to the 30cm long dry air tube into the module cooling unit which is an ID/OD=1.8mm/3.0mm blue tube from CERN shipment (same as the vacuum tube). This transition uses a similar strategy as the vacuum tubes, with a pair of Aluminum low-pressure 1/4 NPT adaptor to barbed tube fitting: 1/4" barb - male NPT (with O-ring) on supply side (McMaster-Carr #5058K441); 1/16" barb and female NPT on module side (McMaster-Carr #5058K641). The initial turn on of dry air should let run for a few hours with the outlet going to the test port using the diverting valve. Check flow and humidity at the test port before flowing into the module cooling unit. Once on for operation, the dry air flow should not be turned off. From an off state, the restart should always have the few hours of initial flush first. During operations, if the dry air needs to be off at the module cooling unit, use the diverting valve to temporarily directing the air to the test port. |
---|
...
long hard polypropylene tubing with 1/4" OD11/64" ID, 1/4" OD~ 80 ft | Diverting Valve with Yor-Lok Fittingsfor 1/4" Tube OD, 316 Stainless Steel BodyLink | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/4" Tube IDx 1/4 NPT Male | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/16"(1.6mm) ID Tube x 1/4 NPT Female | cern tubeOD/ID=3mm/1.8mm(~30cm) |
---|---|---|---|---|
one to application/ one to testing area |
...