Left pump port with 3/8" barb | High-Pressure Firm Polyurethane Rubber TubingID:OD=3/8":5/8" Link ~1.5 m | 316 Stainless Steel Push-on Hose Fitting for Air and Water3/8" Hose ID, 1/4 NPT Male End Link | On/off valve High-Pressure Compact 316 Stainless Steel On/Off Valvewith Lever Handle, 1/4 NPT Female x 1/4 NPT MaleLink | 1/4" Tee316 Stainless Steel Threaded Pipe FittingLow-Pressure, Tee Connector, 1/4 NPT Female | Plastic Barbed Tube Fitting for Air and WaterSwivel Adapter, for 1/16" Tube ID (1.6 mm)x 1/4 NPT Male | cern tube OD/ID=3mm/1.8mm (~30cm) |
---|---|---|---|---|---|---|
to be connect to Remotely monitor vacuum: |
Dry Air
The dry air filters were saved by Matt from BaBar, residing inside the curtained area of B84 EPP lab. House compressed air are filtered to let out through the flow meter with a max flow of 20 ft3/min. A 80ft long hard polypropylene tubing with 1/4" OD (McMaster-Carr #9349T2) takes the drive air down to the ATLAS benches. The dry air supply tube terminates at a diverting valve (no shutoff) (McMaster #45165K42) on the bench to allow the switching of the dry air between a test port and the through path to module cooling unit. The through path continues with the same type of tube to transition to the 30cm long dry air tube into the module cooling unit which is an ID/OD=1.8mm/3.0mm blue tube from CERN shipment (same as the vacuum tube). This transition uses a similar strategy as the vacuum tubes, with a pair of Aluminum low-pressure 1/4 NPT adaptor to barbed tube fitting: 1/4" barb - male NPT (with O-ring) on supply side (McMaster-Carr #5058K441); 1/16" barb and female NPT on module side (McMaster-Carr #5058K641). The initial turn on of dry air should let run for a few hours with the outlet going to the test port using the diverting valve. Check flow and humidity at the test port before flowing into the module cooling unit. Once on for operation, the dry air flow should not be turned off. From an off state, the restart should always have the few hours of initial flush first. During operations, if the dry air needs to be off at the module cooling unit, use the diverting valve to temporarily directing the air to the test port. |
---|
...
long hard polypropylene tubing with 1/4" OD11/64" ID, 1/4" OD~ 80 ft | Diverting Valve with Yor-Lok Fittingsfor 1/4" Tube OD, 316 Stainless Steel BodyLink | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/4" Tube IDx 1/4 NPT Male | Aluminum Low-Pressure Barbed Tube Fittingfor Air and Water, Adapter for 1/16"(1.6mm) ID Tube x 1/4 NPT Female | cern tube OD/ID=3mm/1.8mm (~30cm) |
---|---|---|---|---|
one to application/ one to testing area |
Peltier
- Peltier: 4 sets to be tested:
- 2 layer peltier (recommend): Laird 108161050003 (53W) and Laird 387004685 (125W)
- 1 Layer peltier: Sheetak SKCM-240-11-T100-NS-TF00-ALO (75W)
- 1 Layer peltier: HP-199-1.4-0.8 (120W)
- 1 Layer peltier: HP-199-1.4-1.15 (175W)
Peltier TE-127-1.0-2.5:
peltier | Laird 387004685 (125W) | HP-199-1.4-0.8 (120W) | HP-199-1.4-1.15 (175W) |
---|---|---|---|
figure | |||
properties | Qmax 125 W | Q max 120 W | Q max 175 W |
data sheet | Link | Link | Link |
measurements | P~ 10W delta T =11 C (without load) | P~9W delta T =12 C P~20W delta T =15 C | P ~ 6W delta T = 6 C P~ 17.5W delta T = 9 C |
Preliminary Setup and Test Result
...