Module QC cooling test setup:
Module:
- Stage 1: test with dummy module ( now we have 6 quards and 1 singlet)
- Stage 2: test with module
Power Supply:
- Power for the peltier: bk precision power supply 9130
Cooling unit:
- Peltier: 4 sets to be tested:
- 2 layer peltier (recommend): Laird 108161050003 (53W) and Laird 387004685 (125W)
- 1 Layer peltier: Sheetak SKCM-240-11-T100-NS-TF00-ALO (75W)
- 1 Layer peltier: HP-199-1.4-0.8 (120W)
- 1 Layer peltier: HP-199-1.4-1.15 (175W)
- Chiller: ThermoCube
- Coolant
- Dry Air
- Vacuum pump
- TIM sheet: Panasonic EYG-S0909LZX2
- Cooling unit foam
Monitoring unit
- Raspberry pie and RTD board
Database: link
- Sensor:
- Temperature sensor: pT100
- T3: module (on the dummy module)
- T2: Vacuum chuck
- T1: Coldplate
- Humidity sensor:SHT85
- H1: Inside foam box
- H2: Inside isolation box
Setup from other group
The ITk pixel module cooling Twiki page is the main source for the common information. This page captures the local module cooling setup information at the SLAC Integration site. A talk by Magne Lauritzen (Jul/7/2020) has some updated status and additional pictures.
...