System Test Description: [can check this details: for Peltier and chiller need to check]

Similar settings are shown here presented by Argonne: link slide6 link2

Equipment setup:

  1. power supply:

    1. current / voltage: 0-10A / 0-32V

    1. Wiener Mpod (2channel, HV/LV)

    2. Rohde and Schwarz HMP4040

  2. Monitoring:

    1. Temperature: NTC

    2. Humidity (inside cooling unit): SHT85, (+/- %RH and +/- 0.1 C)

    3. Humidity (inside cold box): Thorlabs TSP01 (+/- accuracy)

    4. Arduino Mega 2560

  3. Cooling:

    1. Cooling unit: qual cooling unit v5

    2. Chiller: Julabo HL CF41

    3. Coolant: 100% silicone oil

    4. Dry, room temperature nitrogen

    5. Room temperature vacuum

    6. TIM sheet: Panasonic EYG-S0909LZX2

    7. TEC combination:

      1. TEC 1: Larid 1081611050003

      2. TEC 2: Larid 387004685